Analysis of wear patterns in linear lines: contamination, preload errors and lubrication deficits

Technical analysis: ALTIVAR58

Analysis of wear patterns in linear lines: contamination, preload errors and lubrication deficits

Introduction: The symptom that triggers the investigation

Unusual wear on the linear lines was observed at a manufacturing plant in the DACH region. The rails showed uneven wear spots extending over a length of 1.2 meters. The cables, type Telemecanique ALTIVAR58, were operated with a maximum load of 25 kN and a speed of 1.5 m/s. The temperature in the area was constantly at 45 °C, which is below the maximum permissible temperature of 60 °C. However, a sudden drop in operating performance was noted, accompanied by irregular noise and vibration.

Overview of the component: function, location and operating conditions

The Telemecanique ALTIVAR58 linear cables are used for the precise guidance of machine axes in industrial systems. They are usually mounted on the machine base plate and carry the load of the moving components. The lines are made of steel and fitted with ball rollers to ensure low friction and high precision. Operating conditions require continuous lubrication to maximize service life and reduce wear.

Evidence of wear and tear: What the technician sees

Visual inspection revealed the following features:

  • Irregular wear spots on the rails, particularly in the middle of the line.
  • A significant loss of lubricant film, indicating inadequate lubrication.
  • Contamination on the surface, probably caused by particles from the environment.
  • The preload was measured using a preload gauge and was within the specified range of 10-15 Nm.
  • Vibration spectrum showed frequencies in the range of 200-300 Hz, indicating uneven load distribution or damage to the rollers.

The temperature of the pipes was 55°C, which is within the acceptable range of 30-70°C, but was an increase compared to the previous service.

Investigation of the cause: systematic analysis

The cause of the wear was analyzed using the Ishikawa diagram and the 5 Whys method. The goal was to identify the causes of uneven wear and lubrication deficits. The following steps were carried out:

1. Visual inspection and measurements

Visual inspection revealed uneven distribution of lubricant film losses, indicating inadequate lubrication. The preload was measured with a preload gauge and was below the recommended range of 10-15 Nm.

2. Vibration spectrum and temperature measurement

The vibration spectrum showed frequencies in the range of 200-300 Hz, indicating uneven load distribution or damage to the rollers. Temperature measurement with an infrared thermometer showed an increase to 55 °C, indicating increased friction.

3. Lubricant analysis

The lubricant was analyzed for particles and contaminants. It was discovered that the lubricant no longer provides sufficient protection and particles from the environment had entered the line.

4. Lubrication cycle and frequency

The lubrication cycle was checked and revealed that lubrication was only performed every 500 hours of operation, which is below the recommended interval of 250-500 hours. Lubrication was performed using a lubrication pump that does not provide continuous lubrication.

5. Preload control

The preload was measured and was within the recommended range of 10-15 Nm. This leads to uneven load distribution and increased friction.

Identified Causes: Ranking with Probability and Evidence

The following causes have been identified as critical:

  1. Contamination of the rails (Probability: 45%) – Contamination in the lubricant and surrounding area leads to uneven wear.
  2. Preload Error (Probability: 30%) – Underwritten preload results in uneven load distribution and increased friction.
  3. Insufficient lubrication (Probability: 20%) – Lubrication cycle too long, lubrication pump not continuous.
  4. Temperature Rise (Probability: 5%) – Increased friction leads to an increase in temperature, which reduces the life of the component.

Remedial measures: Immediate and long-term prevention

For each identified cause, the following actions were suggested:

  1. Contamination
    • Immediate action: Clean the rails with a lubricant cleaner and replace the lubricant.
    • Long-term prevention: Regular cleaning of the rails and lubrication with a lubricant that keeps out particles.
  2. Preload error
    • Immediate action: Readjust the preload using a preload measuring device.
    • Long-term prevention: Regularly check the preload and adjust it when the load or speed changes.
  3. Inadequate lubrication
    • Immediate action: Replacement of the lubrication pump and connection of a continuous lubrication system.
    • Long-term prevention: Regular inspection of the lubrication system and adjustment of lubrication cycles.
  4. Temperature rise
    • Immediate action: Check temperature and adjust lubrication to reduce temperature rise.
    • Long-term prevention: Install a temperature control to control temperature rise.

Practical diagnostic checklist: 10 points for the technician

A technician can check the following points on a tablet to identify possible causes of wear on linear lines:

  1. Check the visual surface of the rails for contamination.
  2. Check the lubrication for sufficient protective function.
  3. Measuring the preload with a preload measuring device.
  4. Check the lubrication cycle and lubrication mechanism.
  5. Check the lubricant level and quality.
  6. Check the temperature of the pipes with an infrared thermometer.
  7. Analyze the vibration spectrum for irregular frequencies.
  8. Check the load distribution and load loading.
  9. Check the lubrication pump for damage or malfunctions.
  10. Check the assembly of the cable for damage or misalignment.

Prevention strategy: maintenance intervals, condition monitoring and design improvements

To avoid later signs of wear and tear, the following measures are recommended:

  • Maintenance intervals: Regular cleaning of the rails every 250 operating hours, lubrication every 500 operating hours.
  • Condition surveillance: Use of vibration sensors and infrared thermometers for continuous monitoring of the pipes.
  • Design improvements: Installation of lubrication pumps with continuous lubrication and use of lubricants with particulate filters.

Summary and CTA

The investigation of the Telemecanique ALTIVAR58 linear lines revealed that contamination, preload errors and insufficient lubrication are the main causes of the uneven wear. By applying the suggested remediation measures and implementing a preventative maintenance strategy, the service life of the component can be significantly extended. For spare parts and preventative components, please visit the UNITEC-D E-Catalog.

References

  • VDI 2852: Lubrication of plain and roller bearings
  • DIN 5441: Ball roller bearings – checking the preload
  • ISO 10426: Lubricant – testing for particles
  • CE Declaration of Conformity – Lubricants and Linear Lines
  • UNITEC-D E-Catalog – spare parts for linear lines

Related Articles