Durag

Showing 1–19 of 19 results
Part Number Manufacturer Description Actions
1112232 Durag D-R 290 SP LP No21. Central board for D-R 290 M, no. 21. Replacement for D-R 290 MK No20. Customs Code No .: 90279050
1112921 Durag D-Skae Sp Lp No10
1116784 Durag D-LX 100 CBL-V1C-PP2-00 connection cable. m. PVC jacket, screen and plastic cable socket, length 1.5 m. used f. D-LX 100/700
1150050 Durag UV-Compact Flame Monitor D-LX 100 UL-P, 24VDC, Spectral Range: 185-260nm, Axial Plug Type M2, IP67, whitout cable
1150050 Durag UV Kompaktflammenwächter D-LX 100 UL-G1/M2/0000/PP2( ex. D-LX 100UL-P)
1150315 Durag D-LE 603 UH-P UV flame sensor
1150513 Durag DLX 100 UA P UV Compact Flame Scanner
1150513 Durag D-LX 100 UA-G1 / M2 / 0000 / PP2. Old name: D-LX 100 UA-P. Region code: G; certified for EU, EAU, USA, CAN. Code: 1; confirmed for applications up to SIL3. UV compact flame monitor. Safety time: 1 sec. 4-20 mA
2029821 Durag ZDAP-150M Gas ignition burner, ionisation-monitored, with integrated ignition transformer and EU type-tested flame monitor Flame relay integrated with 1 potential-free changeover contact Operating mode: Continuous operation EL connection: 10-pole plug connection Connection voltage: 230V 50/60Hz Protection class: IP 54 Pipe length: 1500 mm Pipe diameter: 35 mm Gas connection: Rp 1/2 Air connection: Rp 1 Thermal output: max. 45 kW Gas type: Natural gas Erf. Gas inlet pressure: 50 - 150 mbar Erf. A
AAL 76 P0D/000 ex (AAL 75 P0D) Durag Flame detector for continuous operation and intermiring operation
All products Durag FLENDER COUPLINGS ARPEX K430 CEF 235 (1) C FLANGE (2) F FLANGE
ASD 75 P01 Durag Automatic burner control for interconnection with ionization-controlled pilot burners ZA ..., ZXA ..., ZAVEX .. Connection voltage 230V (+ 10% -15%) 50/60 Hz, 20 VA. IP40
D-LX 110 Durag D-LX 110 UA-C1/M4/84EX/MCG UV compact flame monitor Direct view version
D-LX 110 CBL-V1C-MP7-00 Durag Connection cable - with PVC jacket, shield and metal cable socket, Length 2 m - use f. D-LX 110/710
D-LX 110 UL-C1/M5/0000/MP7 Durag UV compact flame monitor Direct view version Region code: C for use in EU, AUS Functional safety code: 1 SIL documents available Power supply: 24VDC Housing M5: Al MP7: Metal connector Spectral range: UV 185-260nm Process connection: viewing tube connection G1 1/4"; purge air connection: G1/2" Protection class (IP/NEMA): IP 65: Protection class (IP/NEMA): NEMA 4X Ambient temperature: -40 ... +70 °C
D-LX 110_710 MAN-DE Durag Betriebsanleitung deutsch, gedruckt
D-LX100UAF-P Durag UV Compact Flame Scanner
D-LX101UA-30 Durag UV Compact Flame Scanner
ZXAEL1-75E25/00AA0 Durag Ignitor