Panametrics
Showing 1–23 of 23 results
| Part Number ▲ | Manufacturer | Description | Actions |
|---|---|---|---|
| 01262 | Panametrics | M2LW-00-000-0. Calibrated M-series probe with thin-layer aluminum oxide moisture sensor manufacturing according to BASEEFA for II 1 G Eex ia IIC T4 (Tamb = 80 ° C). Process connection: 3/4-inch straight threaded connection with Viton O-ring Area of ??application: For use with a System 1/2, System 250, System 280, MIS1, MIS2, MMS3, MMS35, MMS35IS, MTS5, PM880, MTS6. Sensor protection cap: stainless steel Temperature thermistor: no calibration range: standard calibration from -80 to + 20 ° C dew / | |
| 01441 | Panametrics | MTS6-3-A-1-0 Single-channel moisture analyzer with LCD display and keyboard, an isolated analog output (voltage or current), two process alarm relays and a fault alarm relay, microSD card slot for data recording Housing: Front panel mounting with display and keyboard, NEMA4X, IP66 Power supply: 230 VAC, EU Schuko 2-pole with earth contact, CEE7 / 7 program: standard program, other: standard desig | |
| 02X1-23(+OCI(10.0)T5-0+MTL706)+02X1-13(+OCI(10.0)T5-0+MTL706) | Panametrics | Oxygen transmitter & sensor + Cable with O2X1-Connector 4-20 mA, 24VDC (OCI(10.0)T5-0) + diode safety barrier (MTL706) | |
| 03471 | Panametrics | MONOEXACT DF150E-PANEL MOUNT Housing for panel mounting Gas: O2 Measuring range: 0-1000 ppm Measuring head type: Coulometric Pressure driven with flow switch Voltage connection: Europe Stainless steel tags: none Battery backup: none Pump (O2): none Pressure regulator (O2): none Stainless steel filter (O2): none Adapter 1/4 "(O2): none Door lock: none Alarm: two alarms Analog output: one isolated 4-20mA output Autocal: none Relay contact: two relay contacts | |
| 03472 | Panametrics | XMO2-1H-31-0-XCAL-611-0 XMO2 thermomagnetic oxygen transmitter Power supply: 24VDC, max 1.3 Amp., Output signal: 4 to 20mA, isolated, interface: RS232 Sample gas inlet / outlet: ¼ “-NPT inside Measuring cell: Weatherproof housing Conformity: Standard Compensation / communication: Compensation for carrier gas Communication via IDM / PanaView software Material: stainless steel 1.4401 (316SS) / Viton O-rings Other: standard design XMO2 calibration Measuring range: 0 to 25% oxygen Compe | |
| 705-1297-00 | Panametrics | MTS 6 Panel-mount-adapter assembly | |
| A(10,0)N2S-0 | Panametrics | Cabel 2-core for MMS35 (N4 (Amphenol) connector | |
| A3430 + BCU-58-40W | Panametrics | Tranducer with 10m cable | |
| All products | Panametrics | FLENDER COUPLINGS ARPEX K430 CEF 235 (1) C FLANGE (2) F FLANGE | |
| AT6-C1-CR05JB-508MM-3-2A-AA-02-M-0 | Panametrics | AT600 Ultrasonic flowmeter for fixed installationConsisting of AT600 electronic measuring device,measuring heads, mounting bracket, measuring head cableand coupling agentIncl. Single-channel versionMeasuring head type: C-RS measuring heads with protective socket,0.5MHz, IP65,Temperature range: -40 to 150°CPipe size: 508 mmCable length: 15 metresPower supply: 13 to 28 VDEOne analogue output (4-20mA)Two alarm contactsDisplay language: GermanStandard units: MetricOther: Standard | |
| LCM188-6HD | Panametrics | Cable | |
| M109-RM | Panametrics | Sonde | |
| M2LR | Panametrics | Analyser Probe | |
| M2LR-00-040-00 | Panametrics | Probe with humidity sensor certificate ATEX Eex ia IIC T4, temperature 20-80°C | |
| MMS35-121-1-100 | Panametrics | Hydrometer moisture monitor 120V; 50/60Hz | |
| MMS35-351-1-000 | Panametrics | Humidity examiner H2 alternating current producer complete with barrier ATEX, measuring probe and cable connection | |
| MTS6-3-1-1-0 | Panametrics | Moisture Series 6 hygrometer, LCD display with keyboard, isolated analog output (current or voltage), 2 process alarm relays, fault, and microSD card slot for data logging. Panel mount configuration with NEMA 4X/IP66 front panel, 230 VAC | |
| U8405006 | Panametrics | Transducer M1054, 10Mhz, D=25" | |
| U8431027 | Panametrics | Sensor USLT S/N 751926 | |
| U8800339 | Panametrics | HD cable LCM-188-4 | |
| V208RM | Panametrics | Ultrasonic detector head, element diameter 0.124" = 3.2 mm, 20Mhz, with interchangeable delay line LCM-74-3 90° Microdot connection | |
| VERIDRI-12R-31-000-0-0(ex 4XIP67)+230-049-01 | Panametrics | Humidity transmitter IP66/NEM4X+Cable | |
| ZBS761 | Panametrics | Barrier zener for circuit to intrinsic emergency for cable and probe humidity ATEX Eex ia IIC T.amb: 20-60°C |