Panametrics

Showing 1–23 of 23 results
Part Number Manufacturer Description Actions
01262 Panametrics M2LW-00-000-0. Calibrated M-series probe with thin-layer aluminum oxide moisture sensor manufacturing according to BASEEFA for II 1 G Eex ia IIC T4 (Tamb = 80 ° C). Process connection: 3/4-inch straight threaded connection with Viton O-ring Area of ??application: For use with a System 1/2, System 250, System 280, MIS1, MIS2, MMS3, MMS35, MMS35IS, MTS5, PM880, MTS6. Sensor protection cap: stainless steel Temperature thermistor: no calibration range: standard calibration from -80 to + 20 ° C dew /
01441 Panametrics MTS6-3-A-1-0 Single-channel moisture analyzer with LCD display and keyboard, an isolated analog output (voltage or current), two process alarm relays and a fault alarm relay, microSD card slot for data recording Housing: Front panel mounting with display and keyboard, NEMA4X, IP66 Power supply: 230 VAC, EU Schuko 2-pole with earth contact, CEE7 / 7 program: standard program, other: standard desig
02X1-23(+OCI(10.0)T5-0+MTL706)+02X1-13(+OCI(10.0)T5-0+MTL706) Panametrics Oxygen transmitter & sensor + Cable with O2X1-Connector 4-20 mA, 24VDC (OCI(10.0)T5-0) + diode safety barrier (MTL706)
03471 Panametrics MONOEXACT DF150E-PANEL MOUNT Housing for panel mounting Gas: O2 Measuring range: 0-1000 ppm Measuring head type: Coulometric Pressure driven with flow switch Voltage connection: Europe Stainless steel tags: none Battery backup: none Pump (O2): none Pressure regulator (O2): none Stainless steel filter (O2): none Adapter 1/4 "(O2): none Door lock: none Alarm: two alarms Analog output: one isolated 4-20mA output Autocal: none Relay contact: two relay contacts
03472 Panametrics XMO2-1H-31-0-XCAL-611-0 XMO2 thermomagnetic oxygen transmitter Power supply: 24VDC, max 1.3 Amp., Output signal: 4 to 20mA, isolated, interface: RS232 Sample gas inlet / outlet: ¼ “-NPT inside Measuring cell: Weatherproof housing Conformity: Standard Compensation / communication: Compensation for carrier gas Communication via IDM / PanaView software Material: stainless steel 1.4401 (316SS) / Viton O-rings Other: standard design XMO2 calibration Measuring range: 0 to 25% oxygen Compe
705-1297-00 Panametrics MTS 6 Panel-mount-adapter assembly
A(10,0)N2S-0 Panametrics Cabel 2-core for MMS35 (N4 (Amphenol) connector
A3430 + BCU-58-40W Panametrics Tranducer with 10m cable
All products Panametrics FLENDER COUPLINGS ARPEX K430 CEF 235 (1) C FLANGE (2) F FLANGE
AT6-C1-CR05JB-508MM-3-2A-AA-02-M-0 Panametrics AT600 Ultrasonic flowmeter for fixed installationConsisting of AT600 electronic measuring device,measuring heads, mounting bracket, measuring head cableand coupling agentIncl. Single-channel versionMeasuring head type: C-RS measuring heads with protective socket,0.5MHz, IP65,Temperature range: -40 to 150°CPipe size: 508 mmCable length: 15 metresPower supply: 13 to 28 VDEOne analogue output (4-20mA)Two alarm contactsDisplay language: GermanStandard units: MetricOther: Standard
LCM188-6HD Panametrics Cable
M109-RM Panametrics Sonde
M2LR Panametrics Analyser Probe
M2LR-00-040-00 Panametrics Probe with humidity sensor certificate ATEX Eex ia IIC T4, temperature 20-80°C
MMS35-121-1-100 Panametrics Hydrometer moisture monitor 120V; 50/60Hz
MMS35-351-1-000 Panametrics Humidity examiner H2 alternating current producer complete with barrier ATEX, measuring probe and cable connection
MTS6-3-1-1-0 Panametrics Moisture Series 6 hygrometer, LCD display with keyboard, isolated analog output (current or voltage), 2 process alarm relays, fault, and microSD card slot for data logging. Panel mount configuration with NEMA 4X/IP66 front panel, 230 VAC
U8405006 Panametrics Transducer M1054, 10Mhz, D=25"
U8431027 Panametrics Sensor USLT S/N 751926
U8800339 Panametrics HD cable LCM-188-4
V208RM Panametrics Ultrasonic detector head, element diameter 0.124" = 3.2 mm, 20Mhz, with interchangeable delay line LCM-74-3 90° Microdot connection
VERIDRI-12R-31-000-0-0(ex 4XIP67)+230-049-01 Panametrics Humidity transmitter IP66/NEM4X+Cable
ZBS761 Panametrics Barrier zener for circuit to intrinsic emergency for cable and probe humidity ATEX Eex ia IIC T.amb: 20-60°C