Yokogawa

Showing 1–50 of 95 results
Part Number Manufacturer Description Actions
00160-603010540 Yokogawa Differential pressure transmitter DPharp EJA110E "Capsule M" - Type: EJA110E-JMS3G-712NN / FF1 / D1 // T12 / N4 / DOCQC
A1512EF Yokogawa Fuse
ADMAG AXF015, DN15, 1/2" ANSi ex.(AE115MG-AA1-LSA) Yokogawa Magnetic Inductive Flow Meter Type: ADMAG AXF015G-EAL1-AA12-42 / SCT
ADMAG AXF100G-ECE1L-AA11-21B Yokogawa Magnetic Inductive Flowmeter ADMAG AXF100, DN100
All products Yokogawa FLENDER COUPLINGS ARPEX K430 CEF 235 (1) C FLANGE (2) F FLANGE
AXG015-CAKF2BA1AH212B-1DA11/GRL/L2/EC ex.(AXF015C-D1AH1L-BA11-21B) Yokogawa Magnetic inductive flow meter ADMAG AXF015, DN15
B9565AW Yokogawa Chart Paper, for UR1000 Recorder
B9900BR Yokogawa Battery assy
B9900JJ Yokogawa Display Assy
B9901AX Yokogawa Ribbon Cassette, SR10000 Compact Recorders, 6 Color
B9968BA Yokogawa Bezel assy
DLM3024-F-HL/LN Yokogawa YOKOGAWA" DIGITAL COLOR OSCILLOSCOPE ART. DLM3024-F-HL / LN, COMPLETE WITH THE FOLLOWING OPTIONS: -N ° 1 POWER SUPPLY FOR ACTIVE DIFFERENTIAL / CURRENT PROBES MODEL P4 -N ° 1 BUILT-IN PRINTER MODEL B5 -N ° 1 SOFT BAG MODEL 701964 -N ° 4 DC TO 100MHZ ISOL
DY015-JBLAD4-4D/KS2/SCT (ex. YF101- AADE4DS3S3) Yokogawa Flowtransmitter
DY100-JBLAD2-4D/KS2/SCT (ex. DY100-ECLAD2-4D/KS1/SCT) Yokogawa Flow meter
E7042UD Yokogawa Zirconia Cell Assembly
EJA110A-ELS4A-99DA/D3/KS2 Yokogawa Digital pressure transmitter DPharp EJA110E, capsule L Type: EJA110E-JLH4G-919DJ/KU22/D3 Capsule L ==> 5 to 100 mbar L Capsule applies only to wetted parts code other than S. Model Code - See Data Sheet GS 01C31B01-01EN PS.Tag Nr. ==> Option /N4 Stainless steel tag plate on request Medium : Please specify when ordering Process temperature [°C] : Ditto Process pressure [mbar] : Ditto Measuring range [mbar or bar] : ditto
EJA110E-FMS5C-917DB/KS26/D3/M01/X2 ex. (EJA 110A -FMS5C-97DA/KS25/LC1/Xl/D3/M01/fl2) Yokogawa DPharp EJA110E digital pressure transmitter
EJA110E-JLH4J-912EB-KU22 Yokogawa - Differential-Calibration (D3): 4 to 20 mA = Please indicate by ordering EJA110E: Differential pressure transmitter -J: 4 to 20 mA DC with digital communication (HART 7 protocol) L: Measurement span: 0.5 to 10 kPa (5 to 100 mbar, H: Wetted parts: Cover Flange SCS14A, Capsule Hastelloy C-276, Vent/Dran plug SUS316, 4: Process connections: with 1/2 NPT female process connector, J: Bolts and nuts: B7 carbon steel -9: Installation: horizontal impulse piping type and left side high pressure,
EJA110E-JMS4G-912EJ/KU22 Yokogawa DPharp EJA110E digital pressure transmitter Type: EJA110E-JMS4G-912EJ/KU22 Option /N4 Stainless steel tag plate on request Medium : Please specify when ordering Process temperature [°C] : Ditto Process pressure [mbar] : Ditto Measuring range [mbar or bar] : ditto Tag No. : Please specify when ordering
EJA110E-JMS4G-919DJ/KU22/D3 Yokogawa Digital pressure transmitter DPharp EJA110E, capsule L Type: EJA110E-JLH4G-919DJ/KU22/D3 Capsule L ==> 5 to 100 mbar L Capsule applies only to wetted parts code other than S. Model Code - See Data Sheet GS 01C31B01-01EN PS.Tag Nr. ==> Option /N4 Stainless steel tag plate on request Medium : Please specify when ordering Process temperature [°C] : Ditto Process pressure [mbar] : Ditto Measuring range [mbar or bar] : ditto
EJA130E-JMS4J-912EB/KU22 Yokogawa Differential Pressure Transmitter EJA_130E Typ: EJA130E-JMS4J-912EB/KU22 - Differential-Calibration (D3): 4 to 20 mA = Please indicate by ordering EJA130E: Differential pressure transmitter -J: 4 to 20 mA DC with digital communication (/HART 7 protocol) M: Measurement span 1 to 100 kPa (4 to 400 inH2O) S: Wetted parts material according to the data sheet 4: Process connections 1/2 NPT female J: Bolts and nuts: B7 carbon steel -9: Installation direction: horizontal piping and left side
EJA510E-JAS4N012DL/T05/N4/M15/KU22/QIC/DOCQCB ex.(EJA510E-JAS4N12DL/KU22/M15/T05/N4) Yokogawa Absolute Pressure Transmitter DPharp EJA510E [Capsule Code A]
EJA510E-JBS7N-012DN/KU22/D3/N4/M15 ex.(EJA510A) Yokogawa Digital absolute pressure transmitter DPharp EJA_510E
EJA530E-JBS4N-022DL/KU22/D4/T06/M15/DOCQCB Yokogawa Digital relative pressure transmitter DPharp EJA530E "capsule B" - overpressure calibration: 4 to 20 mA = 1 to 20 kgf / cm2. Equipped with the following options: EJA530E: Relative pressure transmitter -J: 4 to 20 mA HART (HART 5 / HART 7 protocol) (HART 5 or HART 7 can be selected. Please specify when ordering.) B: Measuring span (capsule B) 1 up to 20 bar, (0.1 to 2 MPa) S: material measured Parts and Process .: SS316L / Hastelloy C-276 (capsule), 4: Process connection: 1/2 "NPT internal thread
EJA530E-JBS7N-022DL/KU22/D4/T06/M15/DOCQCB Yokogawa Digital relative pressure transmitter DPharp EJA530E "Capsule B - Overpressure calibration: 4 to 20 mA = 1 to 20 kgf / cm2. Equipped with the following options: EJA530E: Relative pressure transmitter -J: 4 to 20 mA HART (HART 5 / HART 7 Protocol) (HART 5 or HART 7 can be selected. Please specify when ordering.) B: Measuring span (capsule B) 1 to 20 bar, S: Material measured parts and process: SS316L / Hastelloy C-276 (capsule), 7: Process connection: 1/2 "NPT external thread, N-0: Standard, 2: s
EJA530E-JCS4N-022DL/KU22/D4/T07/M15/DOCQCB Yokogawa Digital relative pressure transmitter DPharp EJA530E "Capsule C - Overpressure calibration: 4 to 20 mA = 5 to 100 kgf / cm. Equipped with the following options: EJA530E: Relative pressure transmitter -J: 4 to 20 mA HART (HART 5 / HART 7 Protocol) (HART 5 or HART 7 can be selected. Please specify when ordering.) C: Measuring range (capsule C) 5 to 100 bar, (0.5 to 10 MPa) S: Material measured parts and process: SS316L / Hastelloy C -276 (capsule), 4: process connection: 1/2 "NPT internal thread,
EJA530E-JDS7N-012EL/KU22 Yokogawa Digital pressure transmitter DPharp EJA_530A
EJX110A-JHS5G-914DN/KU22/QIC - 0 bis 0.1 bar Yokogawa DP transmitter EJX110A [0 to 0.1 bar] Type: EJX110A-JHS5G-914DN/KU22/QIC - Differential pressure calibration (D3): 4 - 20 mA = 0 to 0.1 bar linear (Please confirm when ordering) Meaning of model code: EJX: Device series of electrical pressure transmitters 110A: differential pressure transmitter, J: 4 to 20 mA DC with digital communication (HART 5-HART 7), H: span (capsule) 2.5 to 500 kPa (0.025 to 5 bar), S: wetted parts: stainless steel, diaphragm: Hastelloy C276, 5: process connect
EJX110A-JHS5G-914DN/KU22/QIC - 0 bis 5 bar Yokogawa DP transmitter EJX110A [0 to 5 bar] Type: EJX110A-JHS5G-914DN/KU22/QIC - Differential pressure calibration (D3): 4 - 20 mA = 0 to 5 bar linear (Please confirm when ordering) Meaning of model code: EJX: Device series of electrical pressure transmitters 110A: differential pressure transmitter, -J: 4 to 20 mA DC with digital communication (HART 5-HART 7), H: span (capsule) 2.5 to 500 kPa (0.025 to 5 bar), S: wetted parts: stainless steel, diaphragm: Hastelloy C276, 5: process connection
EJX110A-JHS5G-919NN/KU22/D3/M01/QIC Yokogawa DP transmitter EJX110A [0 to 0.1 bar] - Differential pressure calibration (D3): 4 - 20 mA = 0 to 0.05 bar Linear
EJX530A-ECS8N-019NN/KU22/M15 Yokogawa Transmitter pressure
FD40V28-20-NC-FN B Yokogawa Immersion fitting FD40V28: Immersion fitting PVC -20: Immersion depth 2 meters-NC: No cable-FN B
FLXA21DPDAAC1NNFNLAN Yokogawa Conductivity analyzer, Topics: 2 Manufacturer''s Name: Yokogawa, DESIGNACION MANUFACTURER: FLXA21-D-P-D-AA-C1-NN-F-N-LA-N-NN TO SCT
FU20-03-T1-NPT Yokogawa These sensors have four separate elements (pH and redox electrode, reference electrode, temperature sensor), allowing simultaneous measurement of pH and ORP (redox) with a single sensor in a robust Ryton or PVDF (FU20), Ryton (FU24) or PVDF (PH20) enabled. The integrated or variopin cable with number code together with the integrated NPT threads on the sensor makes installation very easy. Equipped with the following options: FU20: pH/ORP (redox) universal sensor FU20, -03: 3m Cable, -T1: Tem
FU20-03-T1-NPT (ex. PH20-F-G-02-T1-N-A) Yokogawa Electrode
FU20-10-T1-FSM Yokogawa Sonde for PH 10m cable Pt1000 Flat surface, 3/4"tap. Thread
FU20-10-T1-NPT Yokogawa Sensor FU20
FU20-20-T1-NPT Yokogawa FU20 Sensor
FU20-VP-T1-FTD Yokogawa Equipped with the following options: FU20: pH / ORP (Redox) universal sensor FU20, -VP: No Cable; Vario Pin connector, -T1: Temp. Sensor Pt1000 -FTD: PVDF body / tapered thread / dome shaped
ISC40G-GG-T1-05 Yokogawa Inductive conductivity sensor ISC40G Type: ISC40G-GG-T1-05 Inductive conductivity sensor for corrosive applications. - Measuring range: 1µS/cm to 2S/cm - Process pressure: max. 20 bar - Process temperature: -20 to +130°C - Process connection: 3/4" thread - Integrated connection cable Equipped with the following options: ISC40G: Inductive conductivity sensor G: For standard applications, -GG: PEEK standard design, -T1: PT1000, -05: 5m cable
K1500BZ Yokogawa O-ring Viton 11x3 (6pcs)
K1500DW Yokogawa Set of 12 cable nuts for WU20
K1520BR Yokogawa Basic holder, PD20-RS-CS-T1
K1520DG Yokogawa Protection cage for PD20
K1520DS Yokogawa Pipe, 2m for PD20
K1520YN Yokogawa PD/PF/PS20 cable, 5m
K1520ZB Yokogawa O-Ring set Viton, for PD20
K1521JE Yokogawa SUPPORT TYPE for FU20 (F) in FF20-F3 * (PVDF)
M3814EY-01 Yokogawa RAMC Float M1 1.4404
M3814FR-01 Yokogawa RAMC retrofit kit damp