Yokogawa
Showing 1–50 of 95 results
| Part Number ▲ | Manufacturer | Description | Actions |
|---|---|---|---|
| 00160-603010540 | Yokogawa | Differential pressure transmitter DPharp EJA110E "Capsule M" - Type: EJA110E-JMS3G-712NN / FF1 / D1 // T12 / N4 / DOCQC | |
| A1512EF | Yokogawa | Fuse | |
| ADMAG AXF015, DN15, 1/2" ANSi ex.(AE115MG-AA1-LSA) | Yokogawa | Magnetic Inductive Flow Meter Type: ADMAG AXF015G-EAL1-AA12-42 / SCT | |
| ADMAG AXF100G-ECE1L-AA11-21B | Yokogawa | Magnetic Inductive Flowmeter ADMAG AXF100, DN100 | |
| All products | Yokogawa | FLENDER COUPLINGS ARPEX K430 CEF 235 (1) C FLANGE (2) F FLANGE | |
| AXG015-CAKF2BA1AH212B-1DA11/GRL/L2/EC ex.(AXF015C-D1AH1L-BA11-21B) | Yokogawa | Magnetic inductive flow meter ADMAG AXF015, DN15 | |
| B9565AW | Yokogawa | Chart Paper, for UR1000 Recorder | |
| B9900BR | Yokogawa | Battery assy | |
| B9900JJ | Yokogawa | Display Assy | |
| B9901AX | Yokogawa | Ribbon Cassette, SR10000 Compact Recorders, 6 Color | |
| B9968BA | Yokogawa | Bezel assy | |
| DLM3024-F-HL/LN | Yokogawa | YOKOGAWA" DIGITAL COLOR OSCILLOSCOPE ART. DLM3024-F-HL / LN, COMPLETE WITH THE FOLLOWING OPTIONS: -N ° 1 POWER SUPPLY FOR ACTIVE DIFFERENTIAL / CURRENT PROBES MODEL P4 -N ° 1 BUILT-IN PRINTER MODEL B5 -N ° 1 SOFT BAG MODEL 701964 -N ° 4 DC TO 100MHZ ISOL | |
| DY015-JBLAD4-4D/KS2/SCT (ex. YF101- AADE4DS3S3) | Yokogawa | Flowtransmitter | |
| DY100-JBLAD2-4D/KS2/SCT (ex. DY100-ECLAD2-4D/KS1/SCT) | Yokogawa | Flow meter | |
| E7042UD | Yokogawa | Zirconia Cell Assembly | |
| EJA110A-ELS4A-99DA/D3/KS2 | Yokogawa | Digital pressure transmitter DPharp EJA110E, capsule L Type: EJA110E-JLH4G-919DJ/KU22/D3 Capsule L ==> 5 to 100 mbar L Capsule applies only to wetted parts code other than S. Model Code - See Data Sheet GS 01C31B01-01EN PS.Tag Nr. ==> Option /N4 Stainless steel tag plate on request Medium : Please specify when ordering Process temperature [°C] : Ditto Process pressure [mbar] : Ditto Measuring range [mbar or bar] : ditto | |
| EJA110E-FMS5C-917DB/KS26/D3/M01/X2 ex. (EJA 110A -FMS5C-97DA/KS25/LC1/Xl/D3/M01/fl2) | Yokogawa | DPharp EJA110E digital pressure transmitter | |
| EJA110E-JLH4J-912EB-KU22 | Yokogawa | - Differential-Calibration (D3): 4 to 20 mA = Please indicate by ordering EJA110E: Differential pressure transmitter -J: 4 to 20 mA DC with digital communication (HART 7 protocol) L: Measurement span: 0.5 to 10 kPa (5 to 100 mbar, H: Wetted parts: Cover Flange SCS14A, Capsule Hastelloy C-276, Vent/Dran plug SUS316, 4: Process connections: with 1/2 NPT female process connector, J: Bolts and nuts: B7 carbon steel -9: Installation: horizontal impulse piping type and left side high pressure, | |
| EJA110E-JMS4G-912EJ/KU22 | Yokogawa | DPharp EJA110E digital pressure transmitter Type: EJA110E-JMS4G-912EJ/KU22 Option /N4 Stainless steel tag plate on request Medium : Please specify when ordering Process temperature [°C] : Ditto Process pressure [mbar] : Ditto Measuring range [mbar or bar] : ditto Tag No. : Please specify when ordering | |
| EJA110E-JMS4G-919DJ/KU22/D3 | Yokogawa | Digital pressure transmitter DPharp EJA110E, capsule L Type: EJA110E-JLH4G-919DJ/KU22/D3 Capsule L ==> 5 to 100 mbar L Capsule applies only to wetted parts code other than S. Model Code - See Data Sheet GS 01C31B01-01EN PS.Tag Nr. ==> Option /N4 Stainless steel tag plate on request Medium : Please specify when ordering Process temperature [°C] : Ditto Process pressure [mbar] : Ditto Measuring range [mbar or bar] : ditto | |
| EJA130E-JMS4J-912EB/KU22 | Yokogawa | Differential Pressure Transmitter EJA_130E Typ: EJA130E-JMS4J-912EB/KU22 - Differential-Calibration (D3): 4 to 20 mA = Please indicate by ordering EJA130E: Differential pressure transmitter -J: 4 to 20 mA DC with digital communication (/HART 7 protocol) M: Measurement span 1 to 100 kPa (4 to 400 inH2O) S: Wetted parts material according to the data sheet 4: Process connections 1/2 NPT female J: Bolts and nuts: B7 carbon steel -9: Installation direction: horizontal piping and left side | |
| EJA510E-JAS4N012DL/T05/N4/M15/KU22/QIC/DOCQCB ex.(EJA510E-JAS4N12DL/KU22/M15/T05/N4) | Yokogawa | Absolute Pressure Transmitter DPharp EJA510E [Capsule Code A] | |
| EJA510E-JBS7N-012DN/KU22/D3/N4/M15 ex.(EJA510A) | Yokogawa | Digital absolute pressure transmitter DPharp EJA_510E | |
| EJA530E-JBS4N-022DL/KU22/D4/T06/M15/DOCQCB | Yokogawa | Digital relative pressure transmitter DPharp EJA530E "capsule B" - overpressure calibration: 4 to 20 mA = 1 to 20 kgf / cm2. Equipped with the following options: EJA530E: Relative pressure transmitter -J: 4 to 20 mA HART (HART 5 / HART 7 protocol) (HART 5 or HART 7 can be selected. Please specify when ordering.) B: Measuring span (capsule B) 1 up to 20 bar, (0.1 to 2 MPa) S: material measured Parts and Process .: SS316L / Hastelloy C-276 (capsule), 4: Process connection: 1/2 "NPT internal thread | |
| EJA530E-JBS7N-022DL/KU22/D4/T06/M15/DOCQCB | Yokogawa | Digital relative pressure transmitter DPharp EJA530E "Capsule B - Overpressure calibration: 4 to 20 mA = 1 to 20 kgf / cm2. Equipped with the following options: EJA530E: Relative pressure transmitter -J: 4 to 20 mA HART (HART 5 / HART 7 Protocol) (HART 5 or HART 7 can be selected. Please specify when ordering.) B: Measuring span (capsule B) 1 to 20 bar, S: Material measured parts and process: SS316L / Hastelloy C-276 (capsule), 7: Process connection: 1/2 "NPT external thread, N-0: Standard, 2: s | |
| EJA530E-JCS4N-022DL/KU22/D4/T07/M15/DOCQCB | Yokogawa | Digital relative pressure transmitter DPharp EJA530E "Capsule C - Overpressure calibration: 4 to 20 mA = 5 to 100 kgf / cm. Equipped with the following options: EJA530E: Relative pressure transmitter -J: 4 to 20 mA HART (HART 5 / HART 7 Protocol) (HART 5 or HART 7 can be selected. Please specify when ordering.) C: Measuring range (capsule C) 5 to 100 bar, (0.5 to 10 MPa) S: Material measured parts and process: SS316L / Hastelloy C -276 (capsule), 4: process connection: 1/2 "NPT internal thread, | |
| EJA530E-JDS7N-012EL/KU22 | Yokogawa | Digital pressure transmitter DPharp EJA_530A | |
| EJX110A-JHS5G-914DN/KU22/QIC - 0 bis 0.1 bar | Yokogawa | DP transmitter EJX110A [0 to 0.1 bar] Type: EJX110A-JHS5G-914DN/KU22/QIC - Differential pressure calibration (D3): 4 - 20 mA = 0 to 0.1 bar linear (Please confirm when ordering) Meaning of model code: EJX: Device series of electrical pressure transmitters 110A: differential pressure transmitter, J: 4 to 20 mA DC with digital communication (HART 5-HART 7), H: span (capsule) 2.5 to 500 kPa (0.025 to 5 bar), S: wetted parts: stainless steel, diaphragm: Hastelloy C276, 5: process connect | |
| EJX110A-JHS5G-914DN/KU22/QIC - 0 bis 5 bar | Yokogawa | DP transmitter EJX110A [0 to 5 bar] Type: EJX110A-JHS5G-914DN/KU22/QIC - Differential pressure calibration (D3): 4 - 20 mA = 0 to 5 bar linear (Please confirm when ordering) Meaning of model code: EJX: Device series of electrical pressure transmitters 110A: differential pressure transmitter, -J: 4 to 20 mA DC with digital communication (HART 5-HART 7), H: span (capsule) 2.5 to 500 kPa (0.025 to 5 bar), S: wetted parts: stainless steel, diaphragm: Hastelloy C276, 5: process connection | |
| EJX110A-JHS5G-919NN/KU22/D3/M01/QIC | Yokogawa | DP transmitter EJX110A [0 to 0.1 bar] - Differential pressure calibration (D3): 4 - 20 mA = 0 to 0.05 bar Linear | |
| EJX530A-ECS8N-019NN/KU22/M15 | Yokogawa | Transmitter pressure | |
| FD40V28-20-NC-FN B | Yokogawa | Immersion fitting FD40V28: Immersion fitting PVC -20: Immersion depth 2 meters-NC: No cable-FN B | |
| FLXA21DPDAAC1NNFNLAN | Yokogawa | Conductivity analyzer, Topics: 2 Manufacturer''s Name: Yokogawa, DESIGNACION MANUFACTURER: FLXA21-D-P-D-AA-C1-NN-F-N-LA-N-NN TO SCT | |
| FU20-03-T1-NPT | Yokogawa | These sensors have four separate elements (pH and redox electrode, reference electrode, temperature sensor), allowing simultaneous measurement of pH and ORP (redox) with a single sensor in a robust Ryton or PVDF (FU20), Ryton (FU24) or PVDF (PH20) enabled. The integrated or variopin cable with number code together with the integrated NPT threads on the sensor makes installation very easy. Equipped with the following options: FU20: pH/ORP (redox) universal sensor FU20, -03: 3m Cable, -T1: Tem | |
| FU20-03-T1-NPT (ex. PH20-F-G-02-T1-N-A) | Yokogawa | Electrode | |
| FU20-10-T1-FSM | Yokogawa | Sonde for PH 10m cable Pt1000 Flat surface, 3/4"tap. Thread | |
| FU20-10-T1-NPT | Yokogawa | Sensor FU20 | |
| FU20-20-T1-NPT | Yokogawa | FU20 Sensor | |
| FU20-VP-T1-FTD | Yokogawa | Equipped with the following options: FU20: pH / ORP (Redox) universal sensor FU20, -VP: No Cable; Vario Pin connector, -T1: Temp. Sensor Pt1000 -FTD: PVDF body / tapered thread / dome shaped | |
| ISC40G-GG-T1-05 | Yokogawa | Inductive conductivity sensor ISC40G Type: ISC40G-GG-T1-05 Inductive conductivity sensor for corrosive applications. - Measuring range: 1µS/cm to 2S/cm - Process pressure: max. 20 bar - Process temperature: -20 to +130°C - Process connection: 3/4" thread - Integrated connection cable Equipped with the following options: ISC40G: Inductive conductivity sensor G: For standard applications, -GG: PEEK standard design, -T1: PT1000, -05: 5m cable | |
| K1500BZ | Yokogawa | O-ring Viton 11x3 (6pcs) | |
| K1500DW | Yokogawa | Set of 12 cable nuts for WU20 | |
| K1520BR | Yokogawa | Basic holder, PD20-RS-CS-T1 | |
| K1520DG | Yokogawa | Protection cage for PD20 | |
| K1520DS | Yokogawa | Pipe, 2m for PD20 | |
| K1520YN | Yokogawa | PD/PF/PS20 cable, 5m | |
| K1520ZB | Yokogawa | O-Ring set Viton, for PD20 | |
| K1521JE | Yokogawa | SUPPORT TYPE for FU20 (F) in FF20-F3 * (PVDF) | |
| M3814EY-01 | Yokogawa | RAMC Float M1 1.4404 | |
| M3814FR-01 | Yokogawa | RAMC retrofit kit damp |