Olympus

Showing 51–100 of 103 results
Part Number Manufacturer Description Actions
Q3300180 Olympus Item: Q3300180 5L32-32X10-A32-P-2.5-OM PROBE Standard-Phased-Array-Prüfkopf, 5 MHz Linien Array, 32 Elements, 32x10 mm active Aperture, 1.00 mm Elementabstand, 10 mm Elementbreite, Gehäuseform A32, Impedanzanpassung auf Rexolite-Vorlaufkeile, PVC-Kabelummantelung, Kabellänge 2,5m, OmniScanStecker
Q4200352 Olympus ABWM-4T-70-AOD2.375IN
Q7000118 Olympus ABWM-4T-70-AOD6.625I
Q7000231 Olympus ABWM-4T-70-AOD10.75IN
Q7000231 Olympus ABWM-4T-70-AOD10.75IN
Q7000325 Olympus ABWM-7T-70-AOD10.00IN- CONTOURED WEDGE
Q7000326 Olympus ABWM-7T-70-AOD8.00IN- CONTOURED WEDGE
Q7000326 ex.(Q000329) Olympus ABWM-7T-70-AOD8.00IN- CONTOURED WEDGE
Q7200422 Olympus SA32C-ULT-N55S-IHC: High-temperature wedge for angle beam phased array probe A32, normal scan, 55-degree shear wave, from ULTEM to steel, with IHC option (irrigation, holes, and carbides). Includes 5 ft of protective sleeve (Q7750078).
Q7200423 Olympus SA31C-ULT-N55S-IHC: High-temperature wedge for angle beam phased array probe A31, normal scan, 55-degree shear wave, from ULTEM to steel, with IHC option (irrigation, holes, and carbides). Includes 5 ft of protective sleeve (Q7750078).
Q7700002 Olympus H-2 Couplant: Temperature range 0 °F (-18 °C) to 750 °F (400 °C) in many open environment applications when used per manufacturer`s recommended procedure.
Q7750078 Olympus 0.3 m (1 ft) of protective sleeve to protect the probe and encoder cables. Nominal diameter of 0.5 in., resists temperatures up to 150 °C.
U8330254 Olympus Item: U8330254 10L16-4.96X5-A00-P-5-OM sample Standard Phased Array Probe, 10 MHz linear array, 16 elements, 4.96x5mm Total Active Aperture, 0.31mm pitch, 5mm elevation, A00 Case Type, Impedance Matching to Rexolite, PVC Sheathing, 5 m Cable Length, Omniscan Connector, Cable Front Exit
U8400020 Olympus M103-SB : Contact Transducer
U8400030 Olympus M110-RM: Ultrasonic contact measuring head, frequency: 5 MHz; Element diameter: approx. 6mm (0.25 "); fingertip housing, right-angled microdot connection.
U8401007 Olympus A103S-RB : Contact Transducer
U8401017 Olympus A106S-RM : Contact Transducer
U8401023 Olympus A108S-RM : Contact Transducer
U8401027 Olympus A109S-RM : Contact Transducer
U8402007 Olympus C133-RM : Contact Transducer
U8403008 Olympus V103-RM : Contact Transducer
U8410014 Olympus Delay Line Transducer Type M205-RM
U8415036 Olympus V2435 : Spot-Weld Transducer, Delay line / water column Spot-Weld transducer. 20MHZ, 0.138in/3.5mm element diameter. For use with DLCW-2003 water column or SWDL-35 / SWDL-37 delay line & SWRR-2 retaining ring (not included).
U8415037 Olympus V2440: Spot Weld Transmitter, Delay Line/Water Column Spot Weld Converter. 20MHz, 0.157"/4.0mm element diameter. For use with DLCW-2003 water column or SWDL-40 / SWDL-42 delay line & SWRR-2 locking ring (not included).
U8415038 Olympus V2445 : Spot-Weld Transducer, Delay line / water column Spot-Weld transducer. 20MHZ, 0.177in/4.5mm element diameter. For use with DLCW-2003 water column or SWDL-45 / SWDL-47 delay line & SWRR-2 retaining ring (not included).
U8415039 Olympus V2450 : Spot-Weld Transducer, Delay line / water column Spot-Weld transducer. 20MHZ, 0.197in/5.0mm element diameter. For use with DLCW-2003 water column or SWDL-50 / SWDL-52 delay line & SWRR-2 retaining ring (not includ)
U8415041 Olympus V2460 : Spot-Weld Transducer, Delay line / water column Spot-Weld transducer. 20MHZ, 0.236in/6.0mm element diameter. For use with DLCW-2003 water column or SWDL-60 / SWDL-62 delay line & SWRR-2 retaining ring (not included)
U8435018 Olympus C541-SM : Angle Beam Transduce- CentraScan ultrasonic angle beam composite: 5.0 MHz, transducer diameter: 12.5 mm (0.5 "), connection: straight microdot
U8435018 Olympus C541-SM: Angle Beam Transducer CentraScan Ultrasonic Angle Probe, Composite: 5.0MHz, Swing diameter: 12.5mm (0.5 "), Connector: Microdot straight
U8435020 Olympus C543-SM : Angle Beam Transduce. Centra-Scan Ultrasonic Angle Probe, Compsite: 5.0 MHz, transducer diameter: approx. 6.4 mm (0.25 "), connection: Microdot straight.
U8435027 Olympus C551-SM : Angle Beam Transduce
U8450018 Olympus D798: Dual transducers Ultrasonic S/E probe; Frequency: 7.5 MHz, element diameter: approx. 7.2mm (0.283"); including cable cast at right angles.
U8450018 ex.(U8454038) Olympus D798: Dual Transducer Ultrasonic S / E test head; Frequency: 7.5 MHz, element diameter: approx. 7.2 mm (0.283 "), encapsulated right-angled cable.
U8450021 Olympus Dual Transducer D799
U8450021 ex.(U84540018) Olympus D799: Dual Transducer Ultrasonic S / E test head; Frequency: 5 MHz; Element diameter: 11,0mm (0,434 "), incl. Molded cable, connector (2 x Lemo 00) right angle.
U8700103 Olympus ABWM-5T-60 : Wedge, Accupath
U8700103 Olympus ABWM-5T-60 : Wedge, Accupath
U8700104 Olympus ABWM-5T-70 : Wedge, Accupath,
U8700104 Olympus ABWM-5T-70 : Wedge, Accupath,
U8700118 Olympus ABWM-7T-60 : Wedge, Accupath,
U8700119 Olympus ABWM-7T-70 : Wedge, AWS, 70 De
U8700119 Olympus ABWM-7T-70 : Wedge, AWS, 70 De
U8770023 Olympus B2: Couplant. Glycerin, 2 oz.Ultrasonic coupling agent glycerin, bottles of 0.06 liter, application range up to 90 ° C
U8770023 Olympus B2: Couplant. Glycerine, 2 oz. Ultrasonic coupling agent glycerin, bottles up to 0.06 liter, application range up to 90 ° C.
U8770049 Olympus DLCW-2003 : Captive water colu
U8780008 Olympus Electric water pump CFU03
U8800154 Olympus BCB-74-6 : Cable. Standard &BN
U8800189 Olympus BCM-74-6 : BNC to MICRODOT. 6
U8800189 Olympus BCM-74-6 : BNC to MICRODOT. 6"
U8800293 Olympus L1CB-58-6: Cable. Standard & L Cable. LEMO to BNC. 6 ft. RG58 / U