WIKA

Showing 301–343 of 343 results
Part Number Manufacturer Description Actions
T32.1S.000-S-KKS-ZZZ-Z WIKA Digital temperature transmitter HART Protocol, model T32, with protocol HART, T32KONF-3KS100I-C1VZZZ-ANNBNB00-ZZZ-Z
T32.1S.0IS.-Z WIKA 12655423, Digital temperature transmitter with HART protocol T32.1S head version 4 ... 20 mA, 2-wire technology Technical data according to data sheet: TE 32.04 (head/rail version T32.xS) Output signal: 4 ... 20 mA, 2-wire technology Input: configurable via software Measuring range: configurable via software Transmitter type: T32.1S head version Explosion protection: without SIL information: not for SIL application HART version: HART® 5 Configuration: Basic configuration (Pt100, 3-wir
T32.3S WIKA 12655458 Digital temperature transmitter T32 with HART-protocol.Specifications according to data sheet: TE 32.04 (head-/railmounting T32.xS).model: T32.3S, rail mounting
T32.S1S1000-Z-KKS-ZZZ-Z (Ex.T32.10.000 V2.0.5) WIKA Temperatur Transmitter 4-20mA;; -40C°+85C°
TR10-H WIKA VA11800.TR10 Industrial Resistance Thermometer TR10-H Head KN4-A U1 = 150mm TR10-H-M-NZZ7SS-2-CRBRM-055-DFK-CD-R -00150-ZZ Equipment Descr. Data sheet: TE60.08: Resistance thermometer without protective tube TR10-H Unit of measurement: Metric (mm)
TR10-H-M-NZZNTA-8-CRBRF-055-DBK-CD-R-00750-ZZ WIKA
TR195 WIKA Cable Resistance Thermometer with Bayonet-Connection
VA11536 WIKA Differential pressure gauge with switches DPGS43.100.250 mbar 2xG 1/2B lower mount. DPGS43.100.311ZPZ-MG225-FCAB-LM-F51-ZZZIZ-ZZZ Specifications according to data sheet: PV 27.05 and AC 08.01 Nominal size:100.switch:inductive switch, ATEX CE EX II 2 GD c TX model 831 first switch operation: makes (1) second switch operation: makes (1) Electrical connection: plug sidewise Scale range: 0-250 mbar2nd Scale or Special Scale: with 2nd scale 0-150 m /h max. static pressure: 6 bar Overpressure safety:
VA11537 WIKA Differential pressure gauge 733.51.100.40mbar 2 x G 1/4 female 733.51-E-8MG140#-AA-UDZZZSZZ-ZZZZ Process industry series All wellded construction Model: 733.51 Specifications according to data sheet: PM 07.05 Case: stainless steel Bezel ring: stainless steel Movement: stainless steel Window: laminated safety glass Case filling: with Case: with pressure blowout disk Nominal size: 100 mm Scale range: 0...40 mbar 2nd Scale or Special Scale: 0 ... 22000 Nm³/h Process connection: 2 x G 1/4 female Con
VA11538 WIKA Bourdon Tube Pressure Gauges, +990.10 233.50.100.2,5 bar G 1/2" female DSS1-MT990.10-123X50-MK1M4-C7H65ZA2-ZZAZZZZZ LABEL-E08DE-ZZZZZ- 233.50-E-BG325Z-CA-UZHZAZZ-ZZZZ H990.10-G2FD6C1C2C1CPZZZZZ Nominal size: 100 mm Scale range: 0...2.5 bar Process connection: Diaphragm Seal Connector location: lower mount Window: laminated safety glass Pointer: adjustable pointer Accuracy class: class 1.0 Material pressure element: Measuring System 316L Case filling fluid: glycerine 86.5% Special measuring elem
VA11539 ex.(M7310.831.22) WIKA Gas actuated thermometer +831.22 F73.100.250°C L1=250x8mm F73.100 C1M-4GD-C0250-N03-4-3-HZZ-ZZZ 831.22Z-AP-Z Specifications according to data sheet: TM 73.01 / TV27.01 Model: F73.100, nominal size 100, with capillary Unit: °C Scale range: 0 °C ... 250 °C Connection design: 4, compression fitting, sliding on stem Process connection: G 1/2 B Stem diameter: 8 mm insertion length L1: 250 mm Capillary: standard capillary stainless steel 1.4571 Capillary length: 3 m Design of case mounting: Surface
VA11540 ex.(7310.831.22) WIKA Gas actuated thermometer +831.22 F73.100.80°C L1=250x8mm F73.100-C1D-4GD-C0250-N03-4-3-HZZ-ZZZ 831.22Z-AP-Z Specifications according to data sheet: TM 73.01 / TV27.01 Model: F73.100, nominal size 100, with capillary Unit: °C Scale range: 0 °C ... 80 °C Connection design: 4, compression fitting, sliding on stem Process connection: G 1/2 B Stem diameter: 8 mm Insertion length L1: 250 mm Capillary: standard capillary stainless steel 1.4571 Capillary length: 3 m Design of case mounting: Surface moun
VA12316 ex.(S5550) WIKA Bimetal thermometer rotatable and swiveling S5550 / 4, NG100, -20 ... + 60 ° C, L1 = 130 x6mm Technical data per data sheet: TM 55.01 Housing: stainless steel Dipping core material: stainless steel Accuracy class: Cl. 1 according to EN 13190 Type of connection: 4, compression fitting slideable to dive shaft Display range: -20 ° C ... +60 ° C Process connection: G 1/2 TUBE shaft diameter: 6 mm Installation length L1: 130 mm Visor: Multi-layer safety glass Zero point correction: Zero point correct
VA12318 ex.(M-7310.831.22) WIKA F73.100-C1F-4GD-C0100-N03-4-3-H1Z-ZZZ 831.22Z-AP-Z Gas actuated thermometer, stainless steel series Specifications according to data sheet: TM 73.01 / TV27.01 Case: stainless steel Stem material: stainless steel Model: F73.100, nominal size 100, with capillary Unit: °C Scale range: 0 °C ... 120 °C Damping: liquid damping Connection design: 4, compression fitting, sliding on stem Process connection: G 1/2 B Stem diameter: 8 mm Insertion length L1: 100 mm Capillary: standard capillary stainless st
VA12319 ex.(H7308.831. 22) WIKA F73.100-C1E-4GD-C0150-N03-1-3-H1Z-ZZZ 831.22Z-AP-Z Gas actuated thermometer, stainless steel series Specifications according to data sheet: TM 73.01 / TV27.01 Case: stainless steel Stem material: stainless steel Model: F73.100, nominal size 100, with capillary Unit: °C Scale range: 0 °C ... 100 °C Damping: liquid damping Connection design: 4, compression fitting, sliding on stem Process connection: G 1/2 B Stem diameter: 8 mm Insertion length L1: 150 mm Capillary: standard capillary stainless st
VA12322 WIKA Glycerine chemistry manometer 233.50.063 10 bar 1/4 NPT rue centr. Cl.1,0 233.50-C-BG410Z-NB-BZEZCZZ-ZZZZ LABEL-PG1DE-ZZZZZ Bourdon Tube Pressure Gauges, Stainless Steel Series Model: 233.50 Specifications according to data sheet: PM 02.02 Measuring system: stainless steel Case filling: with Nominal size: 063 mm Scale range: 0...10 bar Process connection: 1/4 NPT Connector location: center back mount Window: polycarbonate Pointer: standard pointer Accuracy class: class 1.0 Material pressure elem
VA12326 WIKA Bimetallic thermometer VA filled R5502 / S, NG 100, 0 ... 100 ° C, L1 = 160x8mm G1 / 2B below Specifications according to data sheet: TM 55.01 Case: stainless steel Stem material: stainless steel Model: R 5502, nominal size 100, location of stem radial Connection design: standard, male thread Unit: °C Scale range: 0 °C ... 100 °C Process connection: G 1/2 B Stem diameter: 8 mm Insertion length L1: 160 mm Window: laminated safety glass Damping: liquid damping Connector location: radial bottom
VA12327 ex.(M-7310.831.2.) WIKA F73.100-C1E-4GD-C0100-N03-4-3-H1Z-ZZZ831.2ZZ-AP-Z Gas actuated thermometer, stainless steel series Specifications according to data sheet: TM 73.01 / Case: stainless steel Stem material: stainless steel Model: F73.100, nominal size 100, with capillary Unit: °C Scale range: 0 °C ... 100 °C Damping: liquid damping Connection design: 4, compression fitting, sliding on stem Process connection: G 1/2 B Stem diameter: 8 mm Insertion length L1: 100 mm Capillary: standard capillary stainless steel 1.457
VA12625 WIKA Digital temperature transmitter T32 4 / 20mA 2-wire.T32.3S.000-Z-5-KKS-ZZZ-ZT32KONF-3ES100I-C ## ZZZ-ANNBNB00-ZZZ-ZDigital temperature transmitter T32 with HART protocol.
VA20966 WIKA Flow monitor DKG-2/4 G 1/2 " Switching range: 1.3 - 4 l / min Oil - density 900kg / m³ viscosity compensated Version: 1.4571 Contact: changeover contact (COC) 250V 1.5A 50VA, IP 65 Minimum load 3VA Operating pressure max. 16 bar Temperature max. 120 ° C Weight: 0.28 kg
VA20967 WIKA Flow monitor DKG-2/8 G 1/2 " Switching range: 2.5 - 8 l / min Oil - density 900kg / m³ viscosity compensated Version: 1.4571 Contact: changeover contact (COC) 250V 1.5A 50VA, IP 65 Minimum load 3VA Operating pressure max. 16 bar Temperature max. 120 ° C Weight: 0.28 kg
VA28735 WIKA TR21-B miniature resistance thermometer sterile process technology, for orbital welding, measuring insert replaceable TR21-B-BTT-CL00000100-6D1CA001109046086-FZZ-ZZZZ
VA30034 WIKA Bourdon tube pressure gauge, stainless steel PG23HP-S
VA30035 WIKA Resistance thermometer in a compact design TR36
ZT2181.00 WIKA Bourdon tube pressure switch, Stainless steel version
ZT2181.00 WIKA Bourdon tube pressure switch, Stainless steel version
ZT2181.00 WIKA Bourdon tube pressure switch, Stainless steel version
ZT2182.00 WIKA Gas-actuated temperature switch, Stainless steel switch enclosure
ZT2288.00 WIKA PG23CP3-D50-E-BG510Z-ND-LBCPHZCZZ-ZZZ 21FD31I3W0ZZ-IZZZZZZ12ZZZ. Model PG23CP Control Panel Gauge. Bourdon Tube Pressure Gauges, (Stainless Steel) Model: PG23CP Specifications according to data sheet: PM 02.24
ZT3710.00 WIKA MG-AUVK10/T15-L500/M350/1 4
ZT3716.00 WIKA ZVSS185/PN25/R48H
ZT3751.00 WIKA BNA-1,5"/300/RF-M2.000-L6 0x2-MRA/SAC-ZVSS225/PN25/
ZT3751.00 WIKA BNA-1,5"/300/RF-M2.150-L6 0x2-MRA/SAC-ZVSS225/PN25/
ZT3751.00 (KSR..) WIKA M/N: BNA-2"/150/RF-M440-V60*2-MRA-1/MA-ZVSS185/PN25/R48H/BGU-A
ZT3752.00 WIKA BNA-2"/150/RF-M410-PP63*3-MRA-1/MA-ZPPS200/BGU-A
ZT4020.00 WIKA DSS1-MF990.27-6UPT20-MK2M8-C7265ZA1-ZZAZZZZZ WA1 LABEL-E08DE-ZZZZZ- ZZZZZ UPT-20-ZZZSZPROBG440CAZS2ZZZPZZZZZZZZZZZZZZZM1000Z ZZFUP H990.27-ASM1011BC1-C1-C2ZZZZZ Z Universal process pressure transmitter UPT Model: UPT-20
ZT4020.00 WIKA DSS1-MF990.27-6IPT10-MK2M8-C7265BA1-ZZAZZZZZ WA1 LABEL-E08DE-ZZZZZ- ZZZZZ IPT-10-R-BBM-CA-PZZRAZC-ZZ ZZZZZZZZZZZZZZZ-ZZZZXQZZZZZZZPV5DSZXZZZ H990.27-ASM1011BC1-C1-C2ZZZZZ Z Pressure Transmitter IPT-10
ZT5322.00 WIKA TGS73.100-L-2ZZRPZ-C1EZ-C L-8GD-C0600-S03-11ZZ-ZZZT 1 GGHFZVBI-AZ1ZZZZZ1ZZ TG S73.100 / 160
ZT5794.00 TR10-H-M-NZZATA-2-DRZZK-025-DBA-CD-R-00395-ZZ 226 ZZZZZMZZZZZ02500445AA WIKA TR10 Industrial RTD Assembly RTD assembly description (Data sheet: TE60.08): RTD assembly without thermowell TR10-H
ZT5794.00 TR10-H-M-NZZATA-2-DRZZK-025-DBA-CD-R-00515-ZZ 226 ZZZZZMZZZZZ02500565AA WIKA 102,6
ZTR22M/1P002300 WIKA Thermo couples with sonde AISI316
Ø-100-0-10BARR1-2 WIKA Photocell v. 0 to 30 metric (10-30V)
Ø-73-0-25BARR1-8 WIKA Ring diameter 70 x 26 x 6.5 mm