Results for "Cable"
Showing 12901–12950 of 15,736 results
| Part Number ▲ | Brand | Description | Actions |
|---|---|---|---|
| INK0205 | Indramat | Cable 400V-100A-35mm/q-NYY4x35mm/q- 4x0.34MM 6MT PSM LWL KDM 980 / 1000 | |
| INK0206 | Indramat | Cable 400V-100A-35mm/q-NYY4x35mm/q- 4x0.34MM 6MT PSM LWL KDM 980 / 1000 | |
| INK0435 | REXROTH | Fiber Optic Cable (LWL) diametre=6mm | |
| INKO250 | Indramat | Cable 400V-100A-35mm/q-NYY4x35mm/q- 4x0.34MM 6MT PSM LWL KDM 980 / 1000 | |
| INS-WX-D + MGP2-E SCHEDA RELÈ PER WX E S (EX DOT INB-S BASE W) | Elettrowatt | OUTDOOR PIN / PROXY TERMINAL -LON BU PIN + PROX terminal with backlit keys. 125Khz e13.56MhzMifare double antenna. Integrated FTT-10 module. Connection cable 3m. shielded. Dimensions130x90x25mm + OPTIONAL CARD. 2IN/2OUT RELAY FOR THERM. WX Door Management Module 2IN / 2OUT, to be installed in enclosure (not supplied). Compatible with WX and S series terminals. Connection via local bus (distmax20mt.) 2 double balanced digital inputs. | |
| INS0108 | Unitec High-Tech-Industrieprod. | Connector with cable gland | |
| INSM-M05-B0.8PS-2C | Di-Soric | Inductive proximity sensor - Inductive proximity sensor Functional principle: inductive Installation type: flush Switching distance: 0.8mm Operating voltage: 10 ... 30 V DC Switching output: pnp, <200 mA, NO No-load current (max.): 10 mA Evaluation: digital Design: thread Special features: simple switching distance Housing material: stainless steel, V2A Size: M5 x 0.5 Ambient temperature, operation: -25 ... +70 ° C Protection class: IP 67 Connection: cable, 2 m, 3-pin | |
| INSOR ID2CA 0814 P 6 | Schönbuch | Special switch with 6 meter PUR cable. MOQ: 10 pieces. | |
| IPT06A10-6SPHM9F2 | Italconnector | IPT06A10-6SPHM9F2 / IPT06A10-6SPHM9F2 6-pin Cable socket with PHM adapter, nickel-plated RoHS: Complies with RoHS Directive 2015/863/EU with exemption 6 (b), 6 (c) Reach: Lead (CAS 7439-92-1), Imidazolidine-2-thiones (CAS 96-45-7) | |
| IR 2011/40 (ex IR2005/30G) | BST | Sensor 3SEOP156765 without cable | |
| IR-SAI11A ( ex IR-SAI11N) | Chino | Stationary radiation thermometer with protective custody IR-ZYCH and cable IR-ZBRC20 lenght 20m | |
| IR15/101600 | Partech Instruments | Fixed Point Sludge Blanket Detection Sensor IR15, cable length 10m, 0-10.000mg/l | |
| IR2001/3/75 | BST | Photocell with special-entry 75mm; cable 3m | |
| IR8/148120 | Partech Instruments | Fixed Point Sludge Blanket Detection Sensor IR8, cable length 10m, 0-30.000mg/l | |
| IRB 90 6397 100-ZN | ABB | Cable | |
| IS Power-IO 8Pin 5m | Cognex | Cable. | |
| is ProUSBx12 | IFAK | Converter USB-Profibus, consisting of each: 10210-1101 is ProUSBx12 device 10231-1001 is per x12 interfaces user documentation 10241-0101 is per CD; 10214-1101 USB Cable | |
| IS-M12-31-4 | Kistler | Material: 18037196 IS-M12-31-4 Inductive switch Type: IS series with cable outlet Circuit type: PNP - normally open Switching distance (Sn ST 37): 4.0 mm Dimensions: M12x1.0 x 31 mm Cable outlet: axial Cable length: 2500 mm / free cable end | |
| ISC40G-GG-T1-05 | Yokogawa | Inductive conductivity sensor ISC40G Type: ISC40G-GG-T1-05 Inductive conductivity sensor for corrosive applications. - Measuring range: 1µS/cm to 2S/cm - Process pressure: max. 20 bar - Process temperature: -20 to +130°C - Process connection: 3/4" thread - Integrated connection cable Equipped with the following options: ISC40G: Inductive conductivity sensor G: For standard applications, -GG: PEEK standard design, -T1: PT1000, -05: 5m cable | |
| ISCANII | GIN | Flow switch 64MB flash with accessories: powersupply iscan 18v, 840mA, Cable Iscan, Kabel D-Sub 25 CL3/TG, binder cable connector, with metal body, box of joint 711 | |
| ISO1VW | Bosch | Electric valve set without cable | |
| isolierung 1/2-gehause/abgas-AV50G | Elster | PB FC M12 PLUG PRO M12 PLUG CONNECTOR WITH RUGGED METAL HOUSING AND FC CONNECTING METHOD,WITH AXIAL CABLE OUTLET, FOR USE WITH ET200PRO, PIN CONNECTOR, (B CODED) PACKAGING UNIT 5 PIECES | |
| isolierung 1C/2C-gehause-AV 50 G | Elster | PB FC M12 PLUG PRO M12 PLUG CONNECTOR WITH RUGGED METAL HOUSING AND FC CONNECTING METHOD,WITH AXIAL CABLE OUTLET, FOR USE WITH ET200PRO, PIN CONNECTOR, (B CODED) PACKAGING UNIT 5 PIECES | |
| ISPS688FA | PANDUIT | Modular Plug, RJ45, Field Terminable, Category 6A, 8-Position, for Use with Solid 24/1 - 22/1 AWG and Stranded 27/7 - 22/7 AWG, Conductor Diameter 1.0 - 1.6mm, UTP and STP Copper Cable | |
| ISV-1184640 + ISV-1153152 +ISV-1331481 + ISV-1287484 + ISV-1183591 + ISV-1196491 | Morin | TV signaling housing on F89 drives Material adapter: POM + 25% GF Material plate: nylon 66 + 30% GF + bracket for mounting accessories according to VDI / VDE 3845 on drives with Hole pattern 30 x 80 or 41.3 x 93.5 Console height: 55mm, material: 1.4301 + TopWorx position monitor TVF-M2WGNMM, aluminum housing with Plastic lid, Position indicator green / red, with 2 microswitches SPDT, IP 66, 2 cable entries M20x1.5, NAMUR shaft, no NAMUR hole pattern, without assembly kit | |
| IT01E+SI75 | Jungmichel | Amplifier + sensorpair incl. 3m cable | |
| IT2SF | Raytek | Infrared probe including cable XXXCB15 4.5 m. | |
| IT8041P | Ramsey | Ramsey junction box, by Thermo Scientific Model IT80-41 For cable connection up to n.4 load cells Plastic box IP56 protection degree Working temperature: -20° ÷ +60° Dimensions: 200 x 150 x 80 mm | |
| ITD 22 A 4 Y95 1024 M SI K4SK15H S 14 (ex.D-37269) | Thalheim | Sine encoders 1024 sine periods / revolution A-, B-, N-gauge UB = 5 VDC ± 10% Vout = sine / cosine 1 Vpp Connection cable: 2.50 m, tangential K4SG15H assembled on the cable Bore Ø14 mm through Degree of protection: IP65 | |
| ITD 41 B10 2048 H NI KR1 E 11 | BAUMER | Material number 11097972. IP65. Encoder. 2048 pulses / revolution. A, B, N track + inversion. HTL UB = 8 - 30 VDC GT power amplifier. Connection cable: 1.00 m radial. Shaft: Ø11 x 30 (32 , 5) mm | |
| ITD 70 A4Y 71024HNIH2SK12S60 | BAUMER | Encoder 1024 pulses /revolution IP54 A-B-N track+ Inversion HTL UB = 8-30 VDC GT amplifier, connection cable: 1.00 m radially, Bore: 60 mm H6 mm throughout H2SG12 on cable assembly, material number: 11059712 (Old Material Number: 314501) | |
| ITD21A4Y82 512H NIKR1E 14 | Unitec High-Tech-Industrieprod. | Encoder material no. 11060029, 512 pulses / revolution IP54, A, B, N-scale inversion HTL UB=8-30 VDC GT amplifier, cable 1m radial, bore 14mm, -20 / +100 ° C, the attachment rate: 21 installed , Old material no. 316 075 | |
| ITD22A4Y951024MNIK4SK15HS14 | Thalheim | Encoder (ex 318520), 1024 pulses / revolution IP65, 14mm bore, 1VssUB = 5V + / -5%, K4SG15H Cord on Cable | |
| IVLS-4PM12-J500 | Cognex | COG JUMPER CABLE 500MM for connecting a Yellow series bar light to a DataMan 300 with an Xpand 15 accessory | |
| IWH 303/200-0,5-KFN-KHN-PKS10 | TWK | Transducer inductive -OUTPUT 4...20mA, increasingly -measuring stroke 200 mm -linearity 0,5 -front ball joint guided "KFN" -ball joint rear "KHN" -connection rad. silicone cable via PG-connector "PKS" -cable length 10 m -cable length 10 m -according to data sheet IWH 10802 | |
| IWN-008-03ex.(4220260403) | ATLAS COPCO | Cable TENSOR DL 3M | |
| IWN-011-Dongle | Unitec High-Tech-Industrieprod. | Dongle with integrated circuit board, connects cables with control | |
| IWN-D-009-03 | Unitec High-Tech-Industrieprod. | Cable AC-HSASK, Version Atlas Copco ST, l= 3m | |
| IWN005-03 | Unitec High-Tech-Industrieprod. | Cable Version Atlas Copco ST 4220263603, l= 3m | |
| IWN005-05 ex(4220263605) | ATLAS COPCO | AC-HSASK (new cable), version Atlas Copco ST, length: 5,0m (11mm Ø) | |
| IZMX-CAS163-1600-SEC-1 | Eaton | Cassette, 3p, 1600 A, IZMX163 + control cable connection | |
| J050N0120M050 | Brad Harrison | Shielded cable L = 5 m. | |
| J050N0126M050 | Brad Harrison | Shielded cable 5m | |
| J12-WKS | ABS | Pump sump contractor series Jumbo (submersible) C/W 20 MTS cable anf CEE Plug and with KS float switch, 1,2 kW 5,2 Amps, 230 V, 1 phase, 50 Hz. 2750 RPM, | |
| J530755006 | Jaeger | Cable plug series Rapid, female 4-pole (4x4mm) | |
| JAG400906455 | Jagenberg | Signal cable 4048 | |
| JC400-A-XY-NN-MA-ZA-S-P (ex.JS3) | Penny+Giles | Joystick three axial, analogously, 0-100% of exit, with main axis, cable exit | |
| Jetcable | Cavotec | 400Hz Connector SP-4 (4 push buttons,1 micro switch and 3 LED) inclusive cold shrink sleeve and casting compound 25 m cable 3x70+3x12+6x4x1mm² | |
| JP-400 SS 1000 (ATEX) | Debem | Drum Transfer Pump/TR Motor, Motor JP-400-Ex, 230V 50Hz, 550W, IP54, stainless steel pump station, multipurpose chemical, hose fittings, Nozzle brass, Potential equalization cable set, Ex-plug Ex-socket (3-pole) | |
| JSR1T/1S | Jokab | Expansion relay 6A 24 VDC, delay etc. RT6/RT7/RT9/JSBR4 Applicable |