Results for "Ring"

Showing 25551–25600 of 26,307 results
Part Number Brand Description Actions
VM-050GR250 Honsberg Flow switch Nominal diameter: DN 50 Connection: G 2 internal thread Housing: Nickel-plated gunmetal Pressure resistance: PN 16 Seal: NBR Media temperature: -20 ... +90 °C Ambient temperature: -20 ... +70 °C Switching range: 50 ... 250 l/min H2OSwitch head: Plastic Adjustment: Scale ring Electrical connection: Plug DIN 43650-A / ISO 4400 Electrical contact: Microswitch Contact rating: 250 V AC 5 A Connection diagram: Changeover contact, connection diagram no. 0.213 Protection class: IP65 Flow dir
VM-STV13/63-100A-KBHF/MKHF VAHLE SPRING CONNECTORS FOR KBHF AND MKLF FOR 13 MM FLAT COPPER, MAX. 100 A
VM160A06VG Hydraulik Ring Pressure reducing valve NG06 160 bar The requested article VM160A06B3 is no longer available and will be replaced by the item on offer.
VM160A16A2 Hydraulik Ring Valve
VM160A25AR Hydraulik Ring Valve
VMY064L10N1P Hydraulik Ring Proportional valve, Ex: (VMX064L110C2P)
VMY160A10V1P (exVM160A16A) Hydraulik Ring Valve body assy
VMZ032S1PBGY4000 SIKA Electromagnetic flow sensor induQ® VMZ03 Measuring tube PVDF, G3/8B external thread DN 3, ID 3mm Electrodes and grounding rings made of Hastelloy C® Material O-rings FKM Measuring range 0.1...2 l/min max. operating pressure 10 bar at 20 °C 8 bar at 40 °C, 6 bar at 60 °C, 5 bar at 80 °C Media temperature -15...80 °C 4-pin connector M12x1 Pin 1: Power supply 12...24 VDC ±10% Pin 2: not connected Pin 3: GND Pin 4: frequency output (push-pull), 10,000 pulses/litre including works test
VN-06A-150W-E Taisei Kogyo FILTERING ELEMENT 20X227 67.5L / MIN
VN0308301C0B110000000000000000 Krohne Flow meter OPTIFLUX 4300 C flow sensor. Nominal diameter DN 65|2-1/2?. Connection DN 65 PN 16 - EN 1092-1. Water medium. Measuring range 0 ... 400 l/min. VN0308301C0B110000000000000000
VN0346504DSK110002P00000000000 Krohne Flow meter type OPTIFLUX 4000 F Sensor OPTIFLUX 4000 F Separate version Nominal diameter DN 40|1-1/2" Connection DN 40 PN 40 Installation length 150 mm|5.91", without seals & rings Flange material steel P250GH Medium temperature -10...+180°C|+14...+356°F. depending on the operating pressure. Sheet steel housing PFA lining Electrodes Low Noise (W-carbide) base HC22 Fixed electrodes with 2 electrode construction Coil insulation class H Protection class IP 66/67 (NEMA 4X/6) accordin
VN21 + V317 Unitec High-Tech-Industrieprod. Flow meter VARIFLUX 6000, T 6080, DN 40 / 1 1/2", DIN 11851 SC, 280 mm, 1.4404, EPDM, 1.4301, PFA, FDA, Hastelloy C, H, max. 140°C, IP 67, EN 60 529, German instructions, GK, PED Gr. 1, 0.3...12 m/s + measuring range IFC 090 K/D Hart Vers. A 10 imp/m3 4..20 mA
VNA21003(opened) OMAL Axial valve, NC, MS/Viton, 3/8 "IG Pneumatic axial valve, single-acting, spring force OPENED, Chrome-plated brass housing, Viton gasket, connection bds. Threaded socket according to DIN 2999, Mounting flange according to NAMUR for the direct cultivation of a Pilot valve. Operating pressure max. 10 bar. Operating temperature of -20°C up to +150°C. Control pressure max. 8 bar.
VNC20003(closed) OMAL Axial valve, NC, MS/Viton, 3/8 "IG Pneumatic axial valve, single-acting, spring force CLOSED, Chrome-plated brass housing, Viton gasket, connection bds. Threaded socket according to DIN 2999, Mounting flange according to NAMUR for the direct cultivation of a Pilot valve. Operating pressure max. 10 bar. Operating temperature of -20°C up to +150°C. Control pressure max. 8 bar.
VNC30008 OMAL Pneumatic Axial Valve, VIP. Control pressure max. 8bar. Operating pressure max 10bar. DN 40/1,1/2". Weight 3,7Kg/each
VOGEVO Berger Vogel GEAR PUMP AGGR. 230/400V, 50HZ 143-012-171+140 Weight: 18.487
VP220 C FD Visiport VP220 C FD with O-Ring
VPLB1652FPJ12AA Allen Bradley Kinetix VP Low Inertia Servo Motor
VR22189 Thomas Locker Spring loaded Cod. VR 22189
VRC1 Thomas Locker Brush ring Art. VRC1
VRD350-110R810 Hydraulik Ring PT: Circuito U-Bead e V-Bead 24 VDC + 20% / 10 % 0,8 A
VRM-M8x 14 mm RUD Ring nut, 1000-kg Recommended payload. VRM. 300 kg Recommended payload-90 °. Net Weight: 0.44 kg.
VRS M16x24mm RUD VIP Starpoint eyebolt VRS, pink. 1500kg.
VRS M30x45mm RUD Rings. 4500 kg
VRS M36x54mm RUD Rings. Art-Nr.:25250000015156
VRS M42x63mm RUD Rings. 9000kg
VRS-F-M12x 18 mm RUD Eyebolt 2000 kg Recommended payload. VRS-F. Net weight: 3 kg.
VRS-F-M14x21 mm RUD Eyebolt, Safe Working Load: 750,00 kg, net weight: 0:42 kg.
VRS-F-M36x54mm RUD Eyebolt, Recommended payload: 16.000 kg. Net weight: 3,6 kg.
VRS-F-M48x 72mm RUD Eyebolt, Permissible Payload: 32.000kg. Loading capacity 90 ° 12.000kg.
VRS-F-M48x72mm RUD Ring screw 12 kg. Loading capacity: 32.000 kg. Net weight: 7,6 kg.
VRS-M24x36mm RUD Eyebolt, Safe Working Load: 8.000 kg. Net weight: 3.44kg.
VRS-M30x45 mm RUD Eyebolt, Recommended payload: 12,000 kg, Net weight: 3 kg.
VRS-M30x45 mm RUD 25250000015154, eye bolt.
VRS-M36x54 mm RUD 25250000015156, eyebolt,
VRS-M36x54 mm, 25250000015156 RUD Rings. 7.000kg VRS M36x54mm
VRS-M42x63 mm RUD 25250000015157, eye bolt
VRS-M42x63mm RUD Eyebolt, Permissible Payload: 24.000kg Net weight: 18.8kg.
VRS-M48x72 mm RUD 25250000015158, eye bolt.
VRZ181 ND282 Heidenhain Display + bearing G 87232 G 3516
VS 0,1 EPO12V 32Q11/4 - Ex + MK13-ATEX VSE Stainless steel 1.4305, Measuring range: 0,01 - 10 l / min at 21 cst.
VS 0,1 GPO 12V-32N11/4 10...28V DC VSE 13000, volume sensor. Measuring range: 0.01--10 l / min at 21 cst.
VS 0,2 GPO12V 32N11/4 - 10…28VDC (ex. VS0.2 GPO 12V-12A11/3 24VDC) VSE Measuring range: 0.02 to 18 l / min at 21 cst.
VS 1 GPO12V VSE VS 1 GPO12V 32N11 / 4 - 10 ... 28VDC Measuring range 0.05 - 80 liters / min at 21 cst.
VS 2 GPO12V 32N11/4 -10…28VDC (ex. VS2 GPO 12V-12A11/3 24VDC) VSE Measuring range: 0.1 to 120 l / min at 21 cst.
VS 38 MSV Landefeld Covering
VS-0168 Brüel & Kjaer Vibration velocity sensorfor use in hazardous areas, 10 m cable Temperature range: -15...+65° C Measuring direction: horizontal Cable length K: 10 m, open end Cable protection: without marking: EX II 2G Ex db IIC T6 Gb EX II 2D Ex tb IIIC T=85°C Db
VS-068 Schenck Vibration speed sensor, 5m cable, temperature range: -40 .. + 80 ° C, measuring direction: horizontal, cable protection: with steel protection hose, material no .: X081242.07
VS-068 Schenck Vibration speed sensor, 5m cable, temperature range: -40 .. + 80 ° C, measuring direction: horizontal, cable protection: with steel protection hose, material no .: X081242.07
VS-068 1/1/1/071 Brüel & Kjaer Vibration velocity meter, measuring direction horizontal, "Bruel & Kjær Vibro" type VS-068 1/1/1/071, sensitivity 100 mV/mm/s, operating temperature range -34 °C to +100 °C, cable length 5 m, threaded hole for M10 mounting