1. Introduction
During a routine audit of a pumping station at a heavy industry enterprise in Dnipro, the chief engineer recorded an unusual acoustic noise on a centrifugal pump supplying hot water with a temperature of 95 °C. The noise resembled the rustling of gravel inside the hull. The level of vibration on the support bearings exceeded the maximum permissible value for ISO 10816-3 and reached 7.8 mm/s RMS in the range from 10 Hz to 1000 Hz. Pump performance dropped by 14% with no visible change in engine speed (1480 rpm). This symptom indicates the development of hydraulic cavitation, a phenomenon that rapidly destroys impellers and body parts due to microscopic hydraulic shocks.
2. Overview of the component
The object of analysis is an industrial pumping unit with a multi-stage hydraulic part, where the critical element of the suction circuit is the suction valve and the filter module (in particular, the analogue of the components of the HYDAC 310948 series). This unit is installed on the supply line of the working medium in front of the main pump to protect against mechanical impurities and maintain a stable pressure.
Operating conditions:
- Working environment: technical water (temperature 95 °C, density 961.9 kg/m³, saturated vapor pressure $p_v = 84.5$ kPa or 0.845 bar).
- Nominal supply: 120 m³/h.
- Operating pressure at the inlet: 0.2 bar (excessive).
- Material execution of the impeller: AISI 316L stainless steel.
In such conditions, the reserve of the anti-cavitation bubble is critically small. Any drop in pressure at the inlet below the calculated one leads to instant boiling of the liquid at reduced pressure with subsequent condensation (pops) in areas of increased pressure.
3. Evidence of refusal
During a detailed inspection of the dismantled impeller and suction module, the following defects were found:
- Erosive wear of the blades: deep caverns (craters) with a diameter of 1 to 4 mm and a depth of up to 3.5 mm are observed on the leading edges of the impeller blades. The surface resembles a sponge, the metal crumbled due to fatigue failure from water hammer.
- Vibration spectrum (FFT): recorded a high amplitude of high-frequency components in the range from 2 kHz to 10 kHz, as well as the appearance of subharmonics at frequencies multiples of 0.33–0.5 of the reversible frequency (cavitation flow disruptions).
- Pressure drop: the pressure drop across the filter element (HYDAC 310948 series) increased to 0.6 bar (with a nominal value of a clean element of 0.12 bar), which indicates its strong contamination.
4. Investigation of the root cause
To determine the root cause of the accident, the method of fault tree analysis (Fault Tree Analysis) was used. Two main directions were highlighted: the hydraulic resistance of the system and the thermal state of the environment.
Hydraulic shock during cavitation creates local pressure peaks of up to 1000 bar on microscopic areas of metal, which exceeds the fatigue limit of stainless steel after only a few hours of operation.
The formula for calculating the required cavitation reserve (NPSHr):
$$NPSHr = rac{v^2}{2g} + \lambda \cdot rac{L}{D} \cdot rac{v^2}{2g}$$
The available cavitation reserve (NPSHa) is determined by the formula:
$$NPSHa = \left( rac{p_{atm} \pm p_g}{ ho \cdot g} ight) - rac{p_v}{ ho \cdot g} - h_s - h_f$$
Where:
- $p_{atm}$ is atmospheric pressure (101.3 kPa);
- $p_g$ is the manometric pressure on the surface of the liquid in the tank;
- $p_v$ is the saturated vapor pressure of the liquid at the operating temperature (84.5 kPa for 95 °C);
- $h_s$ is the geometric suction height;
- $h_f$ — pressure losses in the suction pipeline and filter.
5. Identified root causes
- Contamination of suction filter (Probability: 65%). Clogged filter element caused additional head loss $h_f = 0.6$ bar, which reduced NPSHa below pump NPSHr level (1.8 m < 2.4 m).
- Increased liquid temperature (Probability: 25%). Increasing the water temperature from the estimated 80 °C to 95 °C increased the saturated vapor pressure $p_v$, automatically reducing the NPSHa.
- Incorrect pipeline geometry (Probability: 10%). Having a shut-off valve too close to the suction port caused flow turbulence.
6. Corrective actions
| The root cause | Immediate elimination (Repair) | Long-term prevention |
|---|---|---|
| Contamination of the filter | Replacing the filter element (hydac analogue 310948) | Installation of a pressure drop sensor with a signal output in the ASKTP |
| High temperature | Lowering the ambient temperature to 80 °C through a heat exchanger | Installation of the start blocking thermostat at $T > 85$ °C |
| Low NPSHa | Increasing support by raising the level of the inlet tank | Modernization of the suction line taking into account the ISO 9906 standard |
7. Quick diagnostic checklist for technicians
Use this checklist when touring equipment using a tablet:
- [ ] Check the readings of the manometer on the suction line (the pressure must be higher than the pressure of saturated steam plus a reserve of 0.5 bar).
- [ ] Evaluate the acoustic noise near the inlet flange of the pump (absence of sound of spilling sand).
- [ ] Read the data from the vibration sensor (RMS should not exceed 4.5 mm/s per ISO 10816-3 for class II).
- [ ] Check the pressure drop on the suction filter (if $\Delta P > 0.25$ bar — cleaning is required).
- [ ] Control the temperature of the environment (compliance with the project documentation).
- [ ] Check the absence of air suction through the seals and flange connections of the suction tract.
- [ ] Inspect the condition of the foundation bolts for loosening from high-frequency vibration.
- [ ] Check the actual flow of liquid on the flow meter with the nominal characteristic of the pump curve.
8. Prevention strategy
To ensure the reliable operation of pumping equipment at Ukrainian factories, the following service standards must be introduced:
- Maintenance intervals: planned revision of filter elements every 500 hours of operation. Replacement of seals and control of the clearance of the impeller — every 8000 hours (MTBF of the pump assembly should be at least 25000 hours).
- Condition monitoring: constant vibration control at frequencies above 1 kHz for early detection of cavitation vortices before the beginning of erosive destruction of metal.
- Quality of components: use of certified spare parts that meet the requirements of technical safety regulations (CE certification, UkrSEPRO). To maintain clean working environments, use proven components from the UNITEC-D E-Catalog.
9. Conclusion
Cavitation is a destructive process that can be fully controlled by regular NPSH calculation, timely cleaning of filter modules and vibration monitoring. Adherence to maintenance regulations and the use of high-quality spare parts extend the service life of pumping equipment many times. Explore the range of reliable industrial components in the UNITEC-D E-Catalog.
10. Links
- ISO 10816-3: Mechanical vibration. Evaluation of machine vibration by measurements on non-rotating parts.
- ISO 9906: Pumps are dynamic. Testing the performance of hydraulic pumps. Accuracy classes 1, 2 and 3.
- DSTU EN 809: General safety requirements for pumps and pumping units for pumping liquids.
- Hydraulic handbook on operation of pumping equipment of industrial enterprises, ed. 2021.