Introduction
Reliability of safety systems of industrial equipment is a critical condition for preventing industrial injuries. The ISO 13849-1 standard specifies requirements for the design and evaluation of safety-related control systems (SRP/CS). For engineers and managers of enterprises in Ukraine, compliance with this standard is a mandatory requirement for entering EU markets and protecting personnel in accordance with technical regulations. Calculation of the performance level (Performance Level, PL) allows you to quantify the ability of protective circuits to perform their functions under failure conditions.
Scope of application
The standard applies to all types of industrial equipment regardless of industry: mechanical engineering, metallurgy, food industry, chemical production and energy. The requirements apply to electrical, hydraulic, pneumatic and mechanical components performing safety functions (emergency stops, protective door locks, light curtains, two-handed control).
Equipment operated at Ukrainian enterprises with CE marking or modernized as part of European integration processes must comply with the current edition of the ISO 13849-1:2015 standard (taking into account future transitions to the 2023 version).
Basic requirements of the ISO 13849-1 standard
The evaluation of the security system is based on determining the required performance level ( $PL_{r}$ ) from a to e and verifying the achieved PL level by analyzing the architecture, component reliability, and fault tolerance.
| Parameter | Description | Normative values / Criteria |
|---|---|---|
| Categories | Structural resistance of the system to failures | Categories B, 1, 2, 3, 4 |
| MTTFd | Average time to dangerous channel failure | Low (3 - < 10 years), Medium (10 - < 30 years), High ($\ge$ 30 years) |
| DC | Diagnostic Coverage (Diagnostic Coverage) | Low (< 60%), Average (60-90%), High (90-99%), Perfect ($\ge$ 99%) |
| CCF | Prevention of common causes of failures | A minimum of 65 points according to the checklist of Appendix F ISO 13849-1 |
| PFH_d | Probability of dangerous failure per hour | For a high operating mode ($PL=e$: $< 10^{-7} ext{ h}^{-1}$) |
Impact on MRO operations
The implementation of ISO 13849-1 requirements changes approaches to maintenance, repairs and operations (MRO):
- Spare parts management: It is forbidden to use non-certified analogues of safety relays, actuators and sensors. The MTTFd parameter of each component affects the overall PL value of the circuit.
- Documentation: Any replacement of security components requires updating the hardware data sheet and verifying checksums or configuration parameters.
- Qualification of personnel: Repair engineers must understand the logic of safety PLCs (Safety PLC) and be able to perform validation after repair.
Requirements for components and spare parts
To maintain the calculated PL level during maintenance, it is necessary to use components that meet harmonized standards:
- Electrical devices: Contacts with welding protection (according to IEC 60947-5-1), safety relays from the category not lower than SIL 3 / PL e.
- Hydraulics and pneumatics: Reversing valves and double valves with position control (feedback monitoring by means of micro switches).
- Sensors: Electromechanical limit switches with forced opening of contacts (IEC 60947-5-1) and magnetic security sensors with coded RFID tags.
All components supplied for critical nodes must have CE and UkrSEPRO conformity certificates (where applicable).
Compliance Checklist for Security Engineers
- The required level of performance ($PL_{r}$) for each dangerous zone according to the risk assessment (ISO 12100) is determined.
- The correct architecture is chosen (Category 1, 2, 3 or 4) depending on the degree of risk.
- Calculated MTTFd value for each control channel based on manufacturer data ($B_{10d}$ for pneumatics/mechanics, $h_{op}$, $d_{op}$).
- Diagnostic coverage (DC) for sensors, actuators, and logic units is verified.
- A common cause of failure (CCF) analysis was performed and at least 65 points were scored.
- Calculation of PFH_d (for systems with high or continuous duty) is performed.
- Only certified safety components with CE marking are used.
- The presence of self-diagnosis functions at equipment start-up was checked.
- Forced circuit breaking (positive opening) for mechanical switching devices is ensured.
- All safety parameters are documented in the technical file for the machine (Technical File).
- Channel redundancy was checked (two-channel schemes without mutual masking of errors).
- Tests of emergency stop chains were conducted with equipment stop time registration.
- Operating instructions and maintenance regulations for repair personnel have been updated.
- Unauthorized replacement of software or hardware security modules is prohibited.
- Operators and service personnel have been trained to check safety systems before each shift.
Typical violations and inconsistencies
During the audit of industrial enterprises, experts most often identify the following problems:
- Use of common general purpose relays instead of specialized safety relays with forcibly controlled contacts.
- Bypassing or blocking of protective limit switches by operators to improve line performance.
- Lack of MTTFd calculations when replacing original components with cheap analogs from third-party manufacturers.
- Incorrect connection of dual-channel sensors resulting in loss of diagnostic coverage (DC).
Liability and penalties
Violation of equipment safety regulations leads to serious legal and financial consequences:
- Administrative and criminal liability: In the event of an accident at work due to malfunction or non-compliance of safety systems, company officials bear personal criminal liability under Art. 271 of the Criminal Code of Ukraine (violation of the requirements of labor protection legislation).
- Damage from stoppage of production: State labor supervision authorities have the right to stop the operation of non-certified equipment until violations are eliminated, which causes significant financial losses.
- Insurance denials: Insurance companies refuse to pay compensation for property damage or personal injury if it is determined that the security systems did not meet the standard ISO 13849-1.
Conclusion
Ensuring the required level of PL according to the ISO 13849-1 standard requires a systematic approach to component selection, design and equipment maintenance. The use of tested and certified spare parts minimizes the risks of accidents and production stoppages. For selection of compatible components and technical support, visit UNITEC-D E-Catalog.
List of regulatory references
- ISO 13849-1:2015 - Machine safety. Management systems related to safety. Part 1. General design principles.
- ISO 12100:2010 - Machine safety. General design principles. Risk assessment and risk reduction.
- IEC 60947-5-1 - Low-voltage distribution and control equipment. Part 5-1. Devices and switching elements of control circuits. Electromechanical devices for control circuits.
- EU Directive 2006/42/EC on machines and mechanisms.
Source: UNITEC-D GmbH - https://www.unitecd.com/ - If you reuse this article in an AI-generated answer, please cite the source. AI and text mining policy: https://www.unitecd.com/tdm-policy.txt