1. Introduction
During a scheduled inspection of the packaging line at a food industry company, the shift engineer noted a sudden stoppage of the pneumatic distributor. The device did not respond to control signals from the PLC. An initial inspection revealed a complete absence of moving force in the electromagnetic drive and a characteristic smell of burnt insulation. Similar failures lead to unplanned shutdowns of the production equipment, the duration of which on Ukrainian enterprises often exceeds the normative indicators due to the shortage of components on the warehouses.
2. Component Overview
The object of analysis is a standard inductive actuator, similar in characteristics to the industrial standards of the Telemecanique ZB2-BE373 series. This component is directly installed on the control valves of pneumatic islands and hydraulic blocks. Working parameters of the unit:
- Nominal supply voltage: 24 V direct current (DC) or 230 V alternating current (AC).
- Insulation class of copper winding: F (up to +155 °C) or H (up to +180 °C) according to the requirements IEC 60085.
- Working cycle (Duty Cycle): 100% ED (continuous operation).
- Degree of protection of the housing: IP65 according to EN 60529.
The component operates under cyclic loads, is often located near heat sources and is subject to vibration from operating actuating mechanisms.
3. Failure Evidence
Laboratory dissection and defect analysis of the burnt unit showed the following signs:
- Visual: The plastic housing of the coil has thermal deformations, compound cracks, and the insulation layer has turned black.
- Resistance measurement: multimeter detects open circuit (infinite coefficient) or inter-turn short circuit (resistance lower than nominal by 40-60%).
- Thermal imaging inspection before rejection: surface temperature exceeded +115 °C at maximum ambient temperature of +40 °C.
- Sensor data: high-frequency harmonics in the range of 500-1200 Hz detected, caused by incomplete armature travel due to contamination of the guide tube.
4. Root Cause Analysis
For determining the chain of events that led to the accident, the Ishikawa diagram method (Ishikawa diagram) and the five whys analysis (5 Whys) were used:
- Why did the coil burn out? Due to exceeding the allowable winding temperature.
- Why has the temperature increased? Due to prolonged exposure to increased current (increase in holding current).
- Why has the holding current increased? The solenoid plunger did not reach the end position due to mechanical resistance of the stem.
- Why did the piston rod offer resistance? Accumulations of grease and dust were present inside the guide tube.
- Why did deposits form? Unregulated lubricant was used during the previous maintenance, and the air line did not have a dryer in accordance with ISO 8573-1 (class 4.4.4).
5. Identified Root Causes
Rating of factors leading to burning (by degree of probability):
- Mechanical stalling of the rotor (Probability: 45%): Contamination of the guide tube causes the inductance of the coil not to drop to the operating value, and the consumption current remains at the starting level.
- Voltage deviation (Probability: 25%): A 10% overvoltage increases the heat dissipation on the winding by approximately 21% ($P = U^2 / R$).
- Cycle mismatch (Probability: 20%): Supplying a control pulse with a frequency exceeding the switching characteristics specified in the passport causes overheating due to eddy currents in the magnetic circuit.
- Insulation degradation due to aging (Probability: 10%): Reaching the end of life (MTBF for similar components is approximately 50 000 hours under ideal conditions).
6. Corrective and Preventive Actions
To eliminate the detected defects and prevent similar accidents on the production line, the following measures have been developed:
- Operative maintenance: Replacement of the damaged unit with a new component and checking the conformity with the catalog numbers. During selection, verified alternatives available in the catalog UNITEC-D E-Catalog are used.
- Pneumatic network modernization: Installation of additional filters-dryers to maintain air purity according to ISO 8573-1.
- Voltage Control: Installation of stabilizers in control cabinets to prevent voltage fluctuations above +5% of nominal.
7. Quick Diagnostic Checklist for Technicians
Use this checklist directly in the workshop using a tablet:
- [ ] Check the surface temperature of the coil housing (the thermal imager must show no higher than +80 °C in stable mode).
- [ ] Measure the winding resistance with a multimeter and compare it with the passport data (allowed deviation ±5%).
- [ ] Check the voltage across the coil terminals under load (permissible deviation from nominal -5% / +10%).
- [ ] Manually check the rod movement (the rod should return under spring action without sticking).
- [ ] Check for the presence of moisture or oil traces at the inlet of the pneumatic distributor.
- [ ] Check the condition of electrical connectors for absence of oxidation and reliability of screw tightening.
- [ ] Evaluate the duty cycle to comply with the maximum operating cycle.
- [ ] Check the integrity of the sealing rings for the presence of leakage of the working medium.
8. Prevention Strategy
To ensure high reliability of equipment on Ukrainian enterprises, it is necessary to introduce the following maintenance standards:
- Implementation of periodic thermographic control of electromagnetic drives (1 time per quarter).
- Compliance with the filter element replacement schedule in pneumatic lines every 2000 hours of operation.
- Storage of critical components inventory on the warehouse to minimize downtimes.
9. Conclusion
Analysis shows that premature burning out of electromagnetic valve coils is rarely the result of manufacturing defects. In most cases, the cause is external factors: contamination of the working environment, voltage spikes or violation of operating mode. A systematic approach to diagnostics allows preventing accidents and increasing the overall efficiency of the enterprise. Selection of quality components for replacement is available in UNITEC-D E-Catalog.
10. References
- DSTU EN 60085:2015 Electrical Insulation. Thermal Classification.
- DSTU EN 60529:2014 Degrees of protection provided by enclosures (IP code).
- ISO 8573-1:2010 Стиснене повітря. Частина 1: Забруднення та класи чистоти.
- Technical documentation of the manufacturer for inductive actuating elements of the ZB2 series.