1. Description of the problem and scope
This manual is intended for senior maintenance engineers, diagnosticians and technicians of Ukrainian industrial enterprises (metallurgy, mechanical engineering, energy, heavy press and foundry sectors). It covers situations where hydraulic actuators (double-acting cylinders, rotary motors) with proportional control exhibit unstable operation, jerks (stick-slip effect), stem self-oscillation, slow response to control commands, or loss of positioning under load.
Symptoms occur on equipment with high requirements for positioning accuracy (presses, CNC machines, continuous casting lines, injection molding machines) that use proportional distributors and servo valves manufactured by Bosch Rexroth, Parker, Moog, Atos, etc.
Classification of the degree of danger (Severity):
- Critical (Critical): Complete loss of control over the movement of the executive mechanism, uncontrolled displacement under load, overheating of the hydraulic unit above 70°C, pressure fluctuations with an amplitude greater than 20% of the working one. Requires Immediate Equipment Stop (LOTO).
- Major: Jerks during positioning, tracking errors within 0.5–2.0 mm, proportional valve control current fluctuations, increased hydraulic distributor noise. It is necessary to carry out diagnostics during the nearest technological window.
- Minor (Minor): Slight fluctuations in speed at low flows that do not directly affect the tolerance of finished products, but indicate initial wear of the spool or degradation of the working fluid.
- Stop the pump station completely and de-energize the drive power supply cabinets. Set the lock on the main switch.
- Relieve the residual pressure in the hydraulic system by opening the relief valves or putting the system in an unloaded state. Check the pressure gauges that the pressure in the pressure line and control lines is 0 bar.
- Discharge the accumulators (if they are in the circuit) by closing the shut-off valves and slowly opening the drain lines to the tank.
- Lock the mechanical part of the actuator (install transport locks, mechanical stops, or lower the cylinder rod to the lower idle position) to prevent it from falling due to gravity or residual spring energy.
- Use personal protective equipment (PPE): safety glasses with side shields, oil-resistant gloves, protective shoes and overalls with fire-resistant or oil-repellent properties. Remember that microflows of liquid under pressure above 70 bar can pierce the skin and cause blood contamination (injection injury).
- Step 1. Checking the nature of oscillations and behavior of the actuator
- Symptom: Actuator rod moves with jerks (stick-slip) at low speed.
- Check the condition of the cylinder guides and seals.
- IF recorded mechanical jamming or wear of anti-friction tapes -> Go to Section 7.1 (Mechanical causes).
- The IF mechanical part is working -> Go to Step 2.
- Check the condition of the cylinder guides and seals.
- Symptom: Self-oscillation (oscillation) of the rod around the given position point.
- Check the parameters of the PID regulator in the control system and the status of the feedback (encoder / ruler).
- The feedback sensor's IR cable is damaged or has interference -> Go to Section 7.2 (Signal Problems).
- The IF settings of the PID controller are too aggressive (high Kp gain) -> Reduce Kp by 15-20% and check stability.
- IF regulator and sensor are normal -> Go to Step 3 (Condition of hydraulic distributor).
- Check the parameters of the PID regulator in the control system and the status of the feedback (encoder / ruler).
- Symptom: Actuator rod moves with jerks (stick-slip) at low speed.
- Step 2. Diagnostics of the electrical signal path
- Measure the supply voltage directly at the proportional valve connector under load with a multimeter.
- IF voltage drops below 22 V DC -> Check the cable cross-section, the condition of the terminal connections and the output power of the power supply unit.
- IF power supply is stable -> Check the control signal (0-10 V / ±10 V / 4-20 mA) with an oscilloscope.
- If there is high high-frequency interference or ripple > 0.5 V -> Check the grounding of the control cable shield (the shield must be connected on one or both sides according to the valve manufacturer's instructions, usually on the control cabinet side).
- Measure the supply voltage directly at the proportional valve connector under load with a multimeter.
- Step 3. Checking the hydraulic part and the proportional valve spool
- Check the condition of the working fluid and the presence of impurities.
- IF cleanliness class worse than ISO 4406 18/16/13 -> Contamination of spool edges with microparticles -> Go to Section 7.3 (Contamination and Wear).
- If there are pressure fluctuations in the P line -> Check the operation of the variable feed pump or the operation of the relief valve.
- Check the condition of the working fluid and the presence of impurities.
- Complete the LOTO cycle (see Section 2). Reduce the pressure to 0 bar, de-energize the electrical circuits.
- Clean the outside surface of the valve and inlet plate of dirt and dust with a solvent-based flush cleaner (do not allow dirt to enter the hydraulic channels!).
- Disconnect the electrical connector, mark with a marker the connection of the hydraulic ports (P, A, B, T, X, Y) to avoid installation errors.
- Carefully unscrew the valve fixing screws (the strength class of the screws must not be lower than 12.9) using a torque wrench. Disassemble the valve together with sealing rings (O-rings).
- Inspect the mounting plate. Check the condition of the sealing seats. Replace the rubber rings (NBR or FKM/Viton material depending on the type of lubricant and temperature). Do not use old or deformed seals.
- Install a new or refurbished proportional valve. Tighten the fastening screws crosswise in several stages according to the manufacturer's rating (for example, for M6 screws - 10 Nm, for M8 - 24 Nm).
- Before turning on the system, bleed the air and check the electrical circuits with a multimeter. Perform spool zero point calibration via the controller software.
- Check the shielding condition of the proportional valve control cable. The screen must have a reliable circular contact (360 degrees) through special EMC clamps with a metal connector body or a ground bus in the distribution cabinet.
- Verify that the resistance between the control cabinet ground terminal and the shop ground circuit is no more than 1 ohm (measure with a microohmmeter).
- In the case of high-resistance ground pins, strip the contact surfaces to bare metal and tighten the threaded connections with the addition of conductive anti-corrosion paste.
- Replace damaged cables with shielded twisted-pair cables (for example, LiYCY or Lapp Kabel ÖLFLEX) with a core cross-section of at least 0.75–1.5 mm², depending on the length of the route.
- ISO 4413: Hydraulic fluid. General rules and safety requirements for systems and their components.
- ISO 4406: Liquid hydraulics. The method of coding the level of pollution by solid particles.
- ISO 1219-1: Hydraulic and pneumatic systems and components. Conventional graphic symbols and schemes.
- OEM Troubleshooting Manuals: Technical documentation of manufacturers of proportional hydraulics (Bosch Rexroth RE 29052, Parker Hannifin Hydraulic Valve Division).
- Accompanied manuals UNITEC-D: "Methodology of washing and cleaning of industrial hydraulic systems under high pressure", "Diagnostics of electromagnetic disturbances in industrial drives with frequency regulation".
The specification meets the requirements of standards ISO 4413 (Hydraulic fluid. General rules and safety requirements for systems and their components), ISO 1219-1 (Conventional graphic symbols) and ISO 4406 (Method of coding the level of contamination by solid particles).
2. Safety measures
CAUTION! HIGH PRESSURE AND STORED ENERGY HAZARD
Before beginning any diagnostic or repair work on the hydraulic system, perform strict Lockout/Tagout (LOTO) procedures:
3. Necessary diagnostic tools
| Name of the tool | Specification / Model | Measurement range | Purpose |
|---|---|---|---|
| Digital multimeter | True RMS (Fluke 87V or similar) | 0-1000 V DC/AC, 0-10 A, 0-50 MΩ | Measurement of supply voltage, task signals 0–10 V / 4–20 mA, coil resistance. |
| Portable oscilloscope | Two-channel (Fluke ScopeMeter or similar) | DC–20 MHz, 0–50 V | Analysis of the waveform of PWM (PWM) control, search for electrical noises and ripples. |
| Digital pressure gauge / Hydrotester | Accuracy class 0.5 (Hydrotechnik, Parker SensoControl) | 0–400 bar, accuracy ±0.1 bar | Measurement of static and dynamic pressure in main lines P, A, B, T. |
| Laser thermometer (Pyrometer) / Thermal imager | Fluke Ti400 or equivalent | -20°C to +250°C, emissivity adjustable | Detection of local overheating zones on the proportional valve, throttles, pump. |
| Portable particle counter | Hydac FCU 1000 or similar | ISO 4406 / NAS 1638 | Assessment of the purity class of the working fluid directly in the system. |
| Vibroanalyzer | SKF / Fluke (vibrator pen with FFT) | 10 Hz–10 kHz, velocity (mm/s), acceleration | Detection of cavitation, water hammer, mechanical resonance of the valve and cylinder. |
4. Initial assessment checklist
Complete this table immediately before starting a detailed diagnosis. All parameters must be fixed under the stabilized operating mode of the equipment.
| Parameter / Observation | Normative value (Permissible) | Actual value | Status (OK / Alarm) |
|---|---|---|---|
| Operating temperature of hydraulic oil | +40°C … +55°C (Max. +65°C) | [ ] | [ ] |
| Pressure in the pressure line (Port P) | Nominal ±2 bar (e.g. 160 bar) | [ ] | [ ] |
| Drain line pressure (Port T) | < 2.5 bar | [ ] | [ ] |
| Lubricant purity class (ISO 4406) | No later than 18/16/13 (according to ISO 4406 for servo systems) | [ ] | [ ] |
| Valve amplifier supply voltage | 24 V DC ±1% (23.76 – 24.24 V) | [ ] | [ ] |
| Valve task signal (Command Signal) | Application compliance (e.g. 0-10 V or 4-20 mA) | [ ] | [ ] |
| Presence of air in the system (foaming in the tank) | Absent, the lubricant is transparent without emulsion | [ ] | [ ] |
| History of errors in the controller (PLC / CNC) | Absence of tracking errors (Following Error) | [ ] | [ ] |
5. Systematic block diagram of diagnostics
Use this decision-making algorithm to sequentially find the fault:
6. Matrix "Symptom - Cause - Diagnosis"
| Symptom | Probable causes (by rank) | Diagnostic test | Expected result when confirming the cause |
|---|---|---|---|
| Jerks and jerky movement at low speed | 1. Wear or destruction of Teflon cylinder seals. 2. Contamination of the working area of the valve spool. 3. The presence of air in the cylinder cavities. |
1. Measurement of internal cylinder leaks (bypass test). 2. Lubricant analysis for purity. 3. System deaeration check. |
1. The passage of lubricant through the cuffs into the drain was detected. 2. The lubricant class is above the norm ISO 18/16/13. 3. The presence of air bubbles when draining from cork valves. |
| Self-oscillation (oscillation) of the rod along the given position | 1. Electrical interference in the feedback cable. 2. The gain of the amplifier is too high. 3. Backlash in the mechanical coupling of the rod with the load. |
1. Oscillography of the feedback signal. 2. Decreased gain settings by 20%. 3. A clock-type indicator on the connection. |
1. The presence of harmonic noises in the sensor signal. 2. Oscillations stop when the gain is reduced. 3. Backlash of mechanics exceeds 0.1 mm. |
| Slow or delayed response to the control signal | 1. Increased internal resistance (clogging) of the spool due to varnish deposits. 2. Supply pressure drop in main line P during load. 3. Valve Onboard Electronics (OBE) failure. |
1. Measuring the temperature of the valve body and checking the operation time. 2. Dynamic manometric control of the line P. 3. Checking the command signal and coil response. |
1. Local overheating, delayed spool movement. 2. Pressure drop by more than 15% of the nominal value. 3. Lack of coil response to small signal increments (less than 5%). |
7. Root Cause Analysis
7.1. Mechanical causes and wear of seals
Why this happens: Long-term operation of the cylinder at high pressures (over 200 bar) and cyclic loads leads to wear of guide rings and pusher seals (for example, polyurethane sleeves and support rings made of bronze fluoroplastic). This causes increased friction of rest compared to friction of movement (stick-slip phenomenon). When the pressure in the cavity increases, the rod "breaks off" too quickly, after which the pressure drops, the rod stops, and the cycle repeats.
How to confirm: Perform an internal flow test. Mechanically block the rod in the middle position, apply the maximum nominal pressure to one of the cavities, blocking the drain from the opposite cavity through a remote manometer or measuring flask. Measure the oil volume flow through the drain or reference port. The permissible internal flow for a high-quality cylinder is no more than 5–10 cm³/min at nominal pressure.
Damage in case of neglect: Complete destruction of sealing elements, burrs on the cylinder mirror (sleeve) and on the piston rod, metal shavings entering the hydraulic circuit, failure of the pumping station.
7.2. Problems of signal integrity and electrical interference
Why this happens: Proportional distributors with a control signal of 0-10V or 4-20mA are extremely sensitive to electromagnetic interference (EMI) generated by frequency converters, powerful electric motors or welding equipment in the shop. Damage to the shielding of the signal cables or oxidation of the contacts in the connectors (for example, DIN 43650 or M12) leads to distortion of the task signal or the feedback signal from the linear position sensor (magnetostrictive transducer).
How to confirm: Connect an oscilloscope to the job signal outputs on the control board or the valve connector. Turn on nearby powerful electric drives. If random peaks, noise with a network frequency of 50 Hz or high-frequency harmonics with an amplitude above 0.1 V appear on the oscillogram, the integrity of the signal path is violated.
Damage if ignored: Chaotic movements of the executive mechanism, operation of emergency safety protections of the machine, premature wear of electromagnet coils due to constant incorrect position adjustments.
7.3. Contamination of the working fluid and degradation of the lubricant
Why this happens: Iron formation, varnish deposits due to overheating of the lubricant above 60°C, as well as the penetration of external contaminants (dust, moisture) lead to the fact that the microgap between the spool and the sleeve of the proportional valve (which is usually only 0.005–0.015 mm) is blocked by particles. The spool loses the linearity of movement, jams in intermediate positions or reacts with a long delay (valve hysteresis increases above the manufacturer's norm by 2-3 times).
How to confirm: Take a sample of the lubricant according to ISO 5555 into a clean container and perform laboratory analysis or measurement with a portable particle counter. A cleanliness class worse than ISO 4406 18/16/13 confirms the presence of a critical level of abrasive particles.
Damage if ignored: Burrs on the precision surfaces of the spool and distributor sleeve, complete valve jamming in one of the positions, the need to completely replace the oversized proportional valve.
8. Step-by-step recovery procedures
8.1. Proportional valve replacement and flushing procedure
8.2. Electromagnetic interference elimination and grounding check procedure
9. Preventive measures
| The root cause | Prevention strategy | Monitoring method | Recommended interval |
|---|---|---|---|
| Contamination of the lubricant with solid particles | Use of fine-cleaning filters (beta coefficient β20(c) ≥ 200) on drain and pressure mains. Control of the filling of the breathers of the hydraulic tank. | Laboratory analysis of lubricant / portable particle counter (ISO 4406). | Every 500 hours of operation (or once a month). |
| Lubricant degradation and varnish formation | Maintaining the operating temperature of the lubricant in the range of +40°C … +55°C with the help of coolers. Use of high-quality hydraulic oils with a high viscosity index (HLP / HVLP). | Thermographic control of the tank and nodes, analysis of the oil acid number (TAN). | Every 2000 hours of operation (or once every 6 months). |
| Oxidation of electrical connections and wear of cables | The use of hermetic connectors with protection not lower than IP67, regular checking of the torques of the terminal screws. | Thermal imaging control of contacts in the electrical cabinet, checking insulation resistance with a megohmmeter. | Every 1000 hours of operation. |
10. Spare parts and components
| Description of the part | Specification | When to replace | Category UNITEC |
|---|---|---|---|
| Proportional distributor (direct or indirect action) | CETOP 03 / NG6, NG10, 24V DC, with built-in electronics (OBE) | When the spool is jammed, the coil is damaged, or the wear exceeds the allowable hysteresis. | Hydraulic components / Proportional valves |
| A set of hydraulic cylinder seals | Polyurethane / FKM (Viton), piston and rod repair kit | When detecting internal flows or external leaks of lubricant along the rod. | Sealing and RTI |
| Pressure / drain filter element | Glass fiber, filtration fineness 5–10 microns (βx(c) ≥ 200) | When the pressure drop sensor (Δp) on the filter housing is activated or according to the regulations. | Filtration and cleaning elements |
| Linear position sensor (magnetostrictive) | 4-20mA or SSI output, custom length (e.g. 0-1000mm) | In the absence of a signal, a jump-like displacement of the position value in the source code. | Sensors and control and measuring devices |