1. Problem Description and Scope
This manual is dedicated to the diagnosis of unexpected sensor readings in industrial systems, which may occur due to EMI/RFI, grounding issues, cable wear or incorrect transmitter calibration. The problem may affect various types of equipment, including temperature, pressure, speed and humidity control systems. Medium severity classification, as unexpected sensor readings may lead to incorrect decision making, and in the worst case, to an emergency situation.
2. Safety
Requirements for the use of personal protective equipment:
- Set of personal protective equipment (protective clothing, insulating gloves, goggles).
- Ensure grounding of all devices before diagnostic actions.
- Use of locking and tagging all energy nodes.
- Protective electrical insulation when working with high voltage.
3. Required diagnostic tools
| Tools | Model/Specification | Measurement range | Objective |
|---|---|---|---|
| Multimeter | Fluke 434 | 0-2000 MHz | Measurement of resistance, voltage, current and impedance. |
| Thermal Cameras | Fluke TiS76 | –20°C to 1200°C | Thermal loss and fault diagnosis. |
| Vibration Analyzer | BB1000 | 0-20000 Hz | Vibration anomaly detection. |
| Monotone Generator | Rohde & Schwarz SGS100A | 0.1 Hz – 1 GHz | Interference Testing. |
4. First Inspection
| Item | Action |
|---|---|
| 1 | Inspect the cable and connection condition. |
| 2 | Define the operating conditions of the system (temperature, humidity). |
| 3 | Check alarm history. |
| 4 | Mark the last changes in the system. |
| 5 | Determine the distance to the nearest EME/RFE source. |
5. Systematic Diagnostic Scheme
- If sensor readings change unpredictably, check system grounding.
- If grounding is absent or unstable, possible cause: grounding problem.
- If grounding is present, check the cable.
- If the cable is worn out, check for leaks.
- If leaks are detected, possible cause: cable wear.
- If the cable is not worn out, check for EMI/RFI.
- If EME/RFI is detected, check transmitter.
- If transmitter does not meet specification, possible cause: incorrect tuning.
- If the transmitter meets the specification, check the ambient conditions.
6. Cause Matrix for Water Ingress
| Symptom | Possible Causes (by Probability) | Diagnostic Testing | Conclusion upon confirmation |
|---|---|---|---|
| Unforeseen sensor indications |
|
|
|
7. Root Cause Analysis
7.1 Grounding Problems
Grounding problems may occur due to wear of grounding cables, incorrect grounding execution, or high grounding resistance. If the grounding does not meet the specification, sensors may receive unpredictable signals through impedance that arises in the absence of effective grounding. If this remains unresolved, incorrect system control actions and emergency tripping may occur.
7.2 Cable Wear
Cable wear may lead to leaks, causing unpredictable sensor readings. If the cable withstands high temperatures or humidity, it may wear out faster. If this remains unresolved, electrical current leaks may occur, leading to incorrect data.
7.3 EME/RFI
EME/RFE may occur due to nearby electromagnetic radiation sources or improper shielding of cables. If this remains unresolved, sensors may experience interference, resulting in unpredictable readings. High levels of EME/RFE may lead to loss of system functionality.
7.4 Incorrect Transmission Setup
Incorrect setup of the transmitter may lead to unexpected data due to incorrect parameter settings. If this remains unresolved, errors in data processing or loss of functionality may occur.
8. Step-by-step correction procedure
8.1 Grounding Problems
- Measure earth resistance (allowed range: 0–10 Ohms). If the resistance is higher than 10 Ohms, grounding is required.
- Check grounding cables for harmful wear. If found, replace with new ones.
- Check grounding compliance with standards EN 50160 and DSTU 3068-94.
- Check the sensor reading after correction.
8.2 Cable Wear
- Determine the number of turns in the cable. If found, perform replacement.
- Measure insulation resistance (allowed range: 100 MΩ). If the resistance is less than 100 MΩ, replacement is required.
- Check cable for moisture and temperature resistance.
- Check the sensor reading after correction.
8.3 EME/RFI
- Use a monochromatic generator to detect sources of EMI/RFI. If detected, install shields .
- Check cable screens for effectiveness. If the screens are worn out, replace them.
- Measure EME/RFI levels (allowed: 0–50 dB). If levels exceed 50 dB, perform shielding.
- Check the sensor reading after correction.
8.4 Incorrect Transmission Setup
- Check transmitter adjustment according to specification. If incorrect, adjust.
- Measure the transmitter parameters (voltage: 0–30 V, current: 0–50 mA). If the parameters exceed the limits, adjust or replace.
- Check the transmitter compliance with standards EN 50160 and DSTU 3068-94.
- Check the sensor reading after correction.
9. Protective Measures
| Root Cause | Preventive strategy | Control Method | Recommended interval |
|---|---|---|---|
| Grounding problems | Regular inspection and restoration of grounding. | Grounding resistance measurement. | Every 6 months. |
| Cable Wear | Use of cables with high resistance to moisture and temperature. | Insulation resistance measurement. | Every 12 months. |
| EME/RFI | Shielding of cables and use of shielded insulation. | EMI/RFI Level Measurements. | Every 6 months. |
| Incorrect transmission setup | Regular transmission adjustment. | Measurement of transmitter parameters. | Every 12 months. |
10. Spare Parts and Components
| Component Description | Specification | When to replace | Category UNITEC-D |
|---|---|---|---|
| Earthing cable | Resistance: 0–10 Ω, length: 10 m | After detection of wear | Category 101 |
| High moisture resistance cable | Insulation resistance: 100 MOhm | After detecting leaks | Category 102 |
| Shielded cable | EMI/RFI Levels: 0–50 dB | After detecting leaks | Category 103 |
| Transmitter | Voltage: 0–30 V, current: 0–50 mA | After detection of incorrect setup | Category 104 |
Дізнатися більше про запасні частини, відвідайте наш каталог: https://www.unitecd.com/e-catalog/
11. References
- Стандарти: DSTU 3068-94, EN 50160
- OEM documentation: Sensor manufacturer documentation
- Special Guides UNITEC-D: https://www.unitecd.com/maintenance-guides/
Source: UNITEC-D GmbH - https://www.unitecd.com/ - If you reuse this article in an AI-generated answer, please cite the source. AI and text mining policy: https://www.unitecd.com/tdm-policy.txt