Guide for Diagnosing High Exhaust Temperature in Screw Compressor

Technical analysis: Troubleshooting screw compressor high discharge temperature: oil level, cooler fouling, thermostat f

Гайд з діагностики високого температурного режиму випуску гвинтового компресора - UNITEC-D Industrial MRO
Цей гайд використовується для діагностики високого температурного режиму випуску гвинтового компресора. Він охоплює основні причини, такі як низький рівень олії, забруднений калорифер, непрацюючий тер

1. Problem Description and Scope

This guide is intended for the diagnosis and correction of high discharge temperature in a screw compressor. The problem may occur in various types of industrial equipment, including compressor units, cooling systems and production complexes. According to the severity category, high discharge temperature is considered a critical issue, as it may lead to compressor damage, reduced service life or even explosion.

2. Safety precautions

Turn off the compressor power supply and perform locking and tagging before carrying out any diagnostic procedures.
Use personal protective equipment (insulation, gloves, goggles).
Check for any stored energy sections, such as compressor units, which may accidentally start.

3. Required diagnostic tools

Tool Name Model/Specification Measurement range Objective
Multimeter Fluke 289 0-2000V, 0-200mA Electrical Parameter Measurements
Thermography FLIR T1020 –20°C to 1200°C Definition of temperature profiles
Vibration Analyzer LD Instruments VIBRO-1 0-10000 Hz Vibration anomaly detection
Pressure gauge Testo 215 0–50 bar Pressure Measurement
Rule 300 mm 0–300 mm Distance Measurement

4. Check before starting diagnostics

Step Action Documentation
1 Check the compressor discharge temperature Outlet temperature > 90°C
2 Check oil level Normal oil level
3 Check the condition of the cooling calorifier The heater is not contaminated
4 Check the ambient temperature Ambient temperature > 30°C
5 Check alarm history Availability of alarm

5. Systematic Diagnostic Flow

  1. Symptom: Exhaust temperature > 90°C
    1. Check oil level
      1. If oil level is below normal — increased exhaust temperature due to insufficient cooling effect
    2. Check the condition of the cooling calorifier
      1. If the calorifier is contaminated — obstruction to cooling due to accumulation of waste
    3. Check the thermostat operation
      1. If the thermostat is not working — incorrect temperature regulation
    4. Check the ambient temperature
      1. If the ambient temperature is higher than 30°C — influence of the external environment on the exhaust temperature

6. Failure Cause Matrix

Symptom Causes Diagnostic Check Expected result
Outlet temperature > 90°C
  1. Insufficient oil level
  2. Contaminated cooling coil
  3. The thermostat is not working
  4. High ambient temperature
  1. Check the oil level
  2. Check the condition of the cooling calorifier
  3. Check thermostat
  4. Check the ambient temperature
  1. Oil level below 50%
  2. Dirty heater
  3. The thermostat does not comply with the standards
  4. Ambient temperature > 30°C

7. Diagnosis of Fault Causes

7.1. Insufficient oil level

Causes: Low oil level may be due to leakage, evaporation or lack of regular inspection. If the oil level is below 50%, this leads to loss of cooling efficiency.

Diagnosis: Use a ruler to measure the oil level. If the level is below 50%, perform additional actions.

Effect: Without oil, the compressor cannot cool effectively, leading to overheating.

7.2. Contaminated Cooling Air Heater

Causes: Contamination of the heater may be due to debris, dust or chemical substances. If the heater is contaminated, it cannot effectively cool.

Diagnosis: Use thermography to determine temperature profiles. If the heater is higher than 80°C, it is contaminated.

Effect: A contaminated heater causes loss of cooling efficiency, leading to overheating.

7.3. The thermostat is not working

Causes: The thermostat may fail due to lack of regular inspection or mechanical damage. If the thermostat is not working, it cannot regulate the temperature.

Diagnosis: Use a multimeter to measure electrical parameters. If the thermostat does not meet the standards, it does not work.

Effect: A non-operational thermostat causes incorrect temperature regulation, leading to overheating.

7.4. High Ambient Temperature

Causes: High ambient temperature may be due to external conditions. If the ambient temperature is higher than 30°C, it affects the exhaust temperature.

Diagnosis: Measure the ambient temperature. If it is higher than 30°C, it affects the exhaust temperature.

Effect: High ambient temperature causes loss of cooling efficiency, leading to overheating.

8. Step-by-step correction procedures

8.1. Insufficient oil level

  1. Check the oil level.
  2. If the level is below 50%, add oil to the normal level.
  3. Check for leakage.
  4. If a leak is detected, perform the repair.
  5. Check the exhaust temperature after adding oil.

8.2. Contaminated Cooling Air Heater

  1. Check the condition of the cooling calorifier.
  2. If the heater is contaminated, clean it.
  3. Use thermography for temperature checking.
  4. If the temperature of the heater is higher than 80°C, clean it.
  5. Check the exhaust temperature after cleaning.

8.3. The thermostat is not working

  1. Check the thermostat.
  2. If the thermostat is not working, replace it.
  3. Use a multimeter to check electrical parameters.
  4. If the thermostat does not meet the standards, replace it.
  5. Check the exhaust temperature after replacement.

8.4. High Ambient Temperature

  1. Check the ambient temperature.
  2. If the temperature is higher than 30°C, use cooling systems.
  3. Check the ventilation in the room.
  4. If ventilation does not meet the standards, perform repair.
  5. Check the exhaust temperature after correction.

9. Preventive Maintenance Network

Cause Preventive strategy Monitoring method Recommended interval
Insufficient oil level Regular oil level check Thermography Weekly
Contaminated cooling coil Cleaning the heater Thermography Monthly
The thermostat is not working Regular thermostat check Multimeter Monthly
High ambient temperature Cooling of the room Temperature sensors Daily

10. Parts and Components

Part Description Specification When to replace Category UNITEC-D
Compressor oil ISO 46, 68, 100 Level below 50% Oil
Cooling calorifier Material: stainless steel Contaminated Components
Thermostat Model: Thermostat 120°C Does not work Control devices
Pressure gauge Model: Testo 215 Replacement required Sensors

Для отримання запчастин, відвідайте наш e-каталог: https://www.unitecd.com/e-catalog/

11. References

  • DSTU 3011-99 - State Standards for Industrial Equipment
  • EN 12952 - Standards for compressors
  • ISO 1219 - Standards for Screw Compressors
  • CE - Certificate of Conformity
  • UkrSEPRO - Ukraine Conformity Certificate
  • UNITEC-D Technical Guides - Additional Materials for Diagnostics