Handbook on alignment: methods of dial indicator and laser alignment with tables of permissible deviations

Technical analysis: Coupling alignment procedure: dial indicator and laser alignment methods with tolerance tables

Handbook on alignment: methods of dial indicator and laser alignment with tables of permissible deviations

1. Purpose and application range

This manual is devoted to the alignment procedure of connections in industrial systems. It is intended for maintenance technicians who perform alignment of connections using dial indicator and laser methods. The procedure is carried out before installation or reconstruction of connections, as well as during regular maintenance to ensure reliable operation of equipment.

2. Safety and Protection

Use of necessary personal protective equipment (PPE): During the alignment process, it is necessary to wear work gloves, goggles and work clothing to prevent injuries from vibrations or accidental contact with electrical components.
Mandatory execution of the lockout and tagging procedure: Before starting any work on alignment of connections, perform locking and securing of electrical or mechanical elements to avoid unexpected incidents.

3. Required Tools and Materials

Tool Name Specification Quantity
Dialineary indicator Range 0–10 mm, temperature range -10°C to +50°C 1
Laser device for leveling Accuracy ±0.01 mm, distance up to 20 m 1
Torque ring Range 0–100 Nm 1
Microscope or micrometer Range 0–25 mm 1
Temperature sensor Range -50°C to +150°C 1
Accessories for laser equipment Clamp, impressions 1

4. Check-list before servicing

Item Check Acceptance/Rejection Criteria Notes
1 Electric system is disconnected Absence of voltage in the network Perform locking and securing
2 Mechanical system is locked out Absence of movement Use locking nuts
3 Cleaned connection Absence of dust and other grinding fluids Use alcohol solution
4 Tools ready All devices in working condition Check compliance with standards EN 60950

5. Step by step procedure

  1. Setting the Base Point

    Mount the dial indicator on a stationary surface to ensure stable measurement. Use a micrometer to determine the distance to 0.01 mm.

    Error: Use of incorrect indicator setup may lead to incorrect measurement.

  2. Deviation Measurement

    Measure the connection deviations using a dial indicator. The permissible deviations are set to 0.05 mm for critical systems. In case of using a laser device, set the reference point and measure the deviations.

    Error: Use of incorrect device parameters may lead to inaccurate results.

  3. Setting the appropriate clearances

    Set the shaft clearance within the range of 0.05–0.15 mm. Use a micrometer or vernier caliper to determine the exact values. If the deviation exceeds 0.2 mm, perform the correction.

    Error: Use of unstable clearances may lead to incorrect function of the connection.

  4. Alignment Execution

    Use the laser alignment instrument to align the shafts. Set the reference point, measure the deviation, and correct under the indicator's guidance. Perform measurements from different angles to ensure full accuracy.

    Error: incorrect installation of the laser device may lead to deviation of results.

  5. Check Results

    After completing the alignment, perform the checking measurements. Use a dial indicator to determine the deviations. Set the value in the range of 0.05–0.15 mm. If the deviation exceeds these values, repeat the process.

    Error: Use of unstable values during measurement may lead to realignment.

6. After Maintenance Checklist

Test Expected result Actual Result Pass/Fail
1 Deviation does not exceed 0.05 mm Measure and record the value
2 Clearance between shafts within the range of 0.05–0.15 mm Measure and record the value
3 No slip during operation Start the system and check

7. Search Diagnostic Table

Symptom Possible cause Correction
Increase of deviations Incorrect alignment Realign the alignment
Reduction of efficiency Insufficient clearance Set the gap within 0.05–0.15 mm
Vibrations during operation Incorrect alignment Align using a laser device

8. Recommended Maintenance Schedule

Task Frequency Estimated duration Skill Level
Alignment of connections Annually 2–3 years Average
Deviation Check Monthly 15–30 minutes Low
Cleaning the connection Quarterly 10–20 minutes Low

9. References to Spare Parts

Part Description Typical Specification Category UNITEC-D
Linear indicator 0–10 mm TOOL-015
Laser device for leveling Accuracy ±0.01 mm TOOL-016
Micrometer 0–25 mm TOOL-017
Torque ring Range 0–100 Nm TOOL-018
Temperature sensor Range -50°C to +150°C TOOL-019

To obtain all the necessary spare parts, visit our catalog: https://www.unitecd.com/e-catalog/

10. References List

This manual complies with the standards:

  • ISO 10426-1:2011 - Methods of Measurement of Gaps
  • EN 13419:2007 - Alignment of Connections
  • DSTU 2315:2005 - Industrial Equipment Maintenance
  • CE, UkrSEPRO certification

Additional documents from the manufacturer and technical recommendations from UNITEC-D GmbH.