Dépannage de la température de décharge élevée du compresseur à vis

Technical analysis: Troubleshooting screw compressor high discharge temperature: oil level, cooler fouling, thermostat f

Dépannage de la température de décharge élevée du compresseur à vis

1. Description et portée du problème

Rotary screw air compressors depend heavily on oil injection for lubrication, sealing, and thermal management. When the discharge temperature exceeds operational thresholds, the unit typically triggers a shutdown to protect against severe mechanical degradation. This diagnostic guide addresses high discharge temperature events (trips occurring above 105 degrees Celsius / 221 degrees Fahrenheit, with warning alarms triggering at 98 degrees Celsius / 208 degrees Fahrenheit) across oil-injected rotary screw compressors operating in automotive, aerospace, food processing, chemical, and general manufacturing facilities. Severity is classified as Critical; continued operation above 110 degrees Celsius / 230 degrees Fahrenheit leads rapidly to varnish formation, oil breakdown, thermal distortion of airend rotors, and catastrophic bearing seizure.

2. Précautions de sécurité

DANGER: HAZARDOUS ENERGY AND STORED PRESSURE

Before initiating any diagnostic or corrective procedure on an industrial screw compressor, execute strict Lockout/Tagout (LOTO) protocols in compliance with OSHA 29 CFR 1910.147 (US) or BS EN 1037 / PUWER (UK). Verify zero mechanical, electrical, and pneumatic energy state.

  • Pneumatic Stored Energy: Isolate the compressor from the plant air header via a lockable ball valve. Verify zero pressure on the air-oil receiver tank pressure gauge before opening any lines. Residual pressure causes sudden fluid expulsion.
  • Thermal Hazards: Discharge piping, oil coolers, airends, and separator vessels operate at extreme temperatures (80 degrees Celsius to 115 degrees Celsius / 176 degrees Fahrenheit to 239 degrees Fahrenheit). Wear heavy insulating leather gloves and safety glasses with side shields (ANSI Z87.1 / EN 166).
  • Electrical Hazards: Voltage up to 690V AC may be present in the starter cabinet. Use a calibrated multimeter to verify zero voltage before inspecting control wiring or temperature RTDs.
  • Personal Protective Equipment (PPE): Flame-retardant coveralls, steel-toe footwear, and hearing protection if operating adjacent to running machinery.

3. Outils de diagnostic requis

Nom de l'outil Spécification / Modèle Plage de mesure But
Multimètre numérique (DMM) CAT III 1 000 V / CAT IV 600 V (par exemple, Fluke 87 V) 0 – 1000V AC/DC, 0 – 50Mohm, 0 – 400mA Check RTD/thermocouple resistance and control circuit voltage.
Imageur thermique infrarouge Resolution 160×120 pixels min. (e.g., Fluke Ti401PRO) -20 degrees Celsius to +500 degrees Celsius Scan oil cooler tubes, thermal valve housing, and discharge piping for thermal differentials.
Analyseur de vibrations FFT capable, 3-axis accelerometer 10 Hz – 10 kHz, 0.1 – 50 mm/s Evaluate airend and motor bearing health during diagnostic run.
Manomètre / Manomètre différentiel Digital differential manometers 0 – 7 bar / 0 – 100 psi Measure pressure drop across air/oil separators and oil filters.
Anémomètre / Compteur de vitesse de l'air Vane or hot-wire anemometer 0.2 – 25 m/s Verify enclosure and room ventilation airflow rates.

4. Liste de contrôle pour l'évaluation initiale

Paramètre / Observation Plage de fonctionnement normale Abnormal Indicator Action/Enregistrement
Ambient Room Temperature +5 degrees Celsius to +40 degrees Celsius > 40 degrees Celsius (104 degrees Fahrenheit) Record exact room temp; check ventilation louvers and exhaust fans.
Operating Discharge Pressure 7.0 bar to 10.0 bar (100 – 145 psi) Running above rated maximum pressure Check plant demand, pressure switch setpoints, and regulator.
Sump Oil Level (Sight Glass) 1/2 to 3/4 full with system stopped/depressurized Below 1/4 or completely opaque/foaming Inspect for oil leaks; note if oil is degraded or contaminated.
Compressor Load Duty Cycle Modulating or Load/Unload (70-90% load) Continuous 100% load with high ambient load Review SCADA/PLC history for recent load profile changes.
Error Log History No prior thermal faults in last 500 hours Recurring warning codes (A04, E12, etc.) Download PLC fault log with timestamps and operating hours.

5. Organigramme de diagnostic systématique

Follow this decision tree systematically from top to bottom. Do not skip steps.

  1. Initial Symptom Verification
    • IF compressor tripped on high discharge temperature (> 105 degrees Celsius):
    • Allow unit to cool to < 40 degrees Celsius before opening panels.
    • Check oil level via receiver sight glass.
      • IF oil level is low: Proceed to Root Cause 1 (Low Oil Level).
      • IF oil level is normal/correct: Proceed to step 2.
  2. Thermal Differential & Cooler Inspection
    • Start compressor in unloaded state or monitor immediately upon startup (if safe).
      • Using thermal imager, scan the oil cooler inlet and outlet lines.
      • IF temperature drop across the oil cooler is less than 8 degrees Celsius (Delta-T < 8 degrees Celsius): Proceed to Root Cause 2 (Cooler Fouling / Blockage).
      • IF temperature drop across the cooler is normal (> 15 degrees Celsius) but oil entering the airend remains hot: Proceed to step 3.
  3. Thermal Bypass Valve Verification
    • Measure temperature of the oil line returning from the cooler versus the bypass line entering the thermostatic valve housing using an infrared thermometer.
      • IF the bypass line remains hot when discharge temperature exceeds opening threshold (typically 60-75 degrees Celsius): Proceed to Root Cause 3 (Thermostatic Valve Failure).
      • IF thermostatic valve operates correctly: Proceed to step 4.
  4. Environmental & Ventilation Assessment
    • Measure ambient temperature at compressor intake and room exhaust.
      • IF ambient temperature > 40 degrees Celsius or ventilation airflow is restricted: Proceed to Root Cause 4 (Adverse Ambient Conditions / Ventilation Failure).
      • IF ambient conditions are within spec: Proceed to Root Cause 5 (Sensor Calibration / Electrical Fault).

6. Matrice des causes de panne

Symptôme Causes probables (classées) Test diagnostique Résultat attendu si la cause est confirmée
Discharge temp reaches 108 degrees Celsius within 15 mins of load. 1. Thermostatic valve stuck closed
2. Low oil level
3. Blocked oil cooler fins
Thermal imaging of valve housing and cooler lines; sight glass check. Bypass line hot, cooler inlet cold; low sight glass; uneven thermal gradient on cooler.
Gradual temperature increase over 2-3 months of operation. 1. External dust/debris on cooler fins
2. Internal oil varnish/sludge
3. Degraded compressor oil
Visual inspection of cooler core; oil sample analysis (ASTM D445 viscosity). Fins caked with particulate; high oil acid number (TAN) and elevated viscosity.
Instantaneous high temp trip on startup with cold pipes. 1. RTD sensor failure / short circuit
2. Loose sensor wiring terminal
Measure RTD resistance (Pt100/Pt1000) with DMM at terminal block. Resistance reading does not match actual ambient temperature curve.
High temp trip only during afternoon peak shift hours. 1. Room exhaust fan failure
2. Ducting static pressure restriction
3. High ambient temperature
Anemometer airflow measurement; room temperature logger review. Airflow below OEM spec (m3/h); room temp exceeding 40 degrees Celsius.

7. Analyse des causes profondes pour chaque défaut

Root Cause 1: Low Oil Level

Explanation: Compressor oil serves a triple function: lubrication, sealing of rotor clearances, and direct heat absorption from the compression chamber. When the oil charge drops below the minimum operating threshold, the smaller volume of oil absorbs the same mechanical and thermodynamic heat load, resulting in a rapid temperature spike. Low oil levels also reduce the oil flow rate through the thermostatic valve and oil cooler, accelerating thermal degradation.

Confirmation: Check the oil receiver sight glass with the compressor shut down and depressurized. If the level is below the minimum mark, or if oil consumption exceeds 0.05% of total mass flow rate, check for external leaks at shaft seals, oil filter gaskets, separator elements, and oil cooler headers.

Consequences: Severe oil starvation leads to direct metal-to-metal contact between male and female rotor lobes, scoring of airend housing bores, rapid bearing cage failure, and total airend seizure requiring complete replacement.

Root Cause 2: Oil Cooler Fouling (External & Internal)

Explanation: Rotary screw compressors utilize air-cooled or water-cooled heat exchangers. External fouling occurs when airborne particulates (dust, lint, paper, chemical mist) are drawn across the aluminum or copper fin pack by the cooling fan, forming an insulating blanket that blocks convective heat transfer. Internal fouling occurs due to carbonization, varnish, and oil oxidation products lining the inner tube walls, restricting thermal conductivity.

Confirmation: Use a thermal imager across the cooler matrix. A fouled cooler exhibits a high temperature differential (Delta-T) across the core face without a corresponding drop in oil temperature, or shows localized cold/hot spots indicating blocked tubes.

Consequences: Reduced heat rejection forces the circulating oil to enter the airend at elevated temperatures (e.g., 70 degrees Celsius instead of 55 degrees Celsius), compounding the compression heat and triggering high-temperature shutdowns.

Root Cause 3: Thermostatic Mixing Valve Failure

Explanation: The thermostatic valve directs compressor oil either directly back to the airend (during cold startup to accelerate warm-up) or through the oil cooler (once normal operating temperature is reached). The internal wax element degrades over time, losing expansion capability, or the sliding spool sticks due to varnish accumulation.

Confirmation: Monitor the oil lines connected to the thermostatic valve body using an infrared thermometer. If the line leading to the oil cooler remains cool while the discharge temperature exceeds 90 degrees Celsius, the valve element is stuck closed, recirculating hot oil directly back into the airend.

Consequences: Total bypass of the cooling circuit prevents heat rejection, causing the oil temperature to escalate exponentially within minutes of loading.

Root Cause 4: Adverse Ambient Conditions & Ventilation Failure

Explanation: Air-cooled compressors reject total electrical and mechanical input energy as heat into the equipment room. If room ventilation capacity (exhaust fan CFM) is inadequate, or if ambient temperatures exceed 40 degrees Celsius (104 degrees Fahrenheit), the temperature differential between the cooling medium (ambient air) and the hot oil diminishes, reducing heat transfer efficiency.

Confirmation: Measure ambient temperature within 1 meter of the compressor air intake using a calibrated thermocouple. Check auxiliary exhaust fan rotation, drive belt tension, and ductwork backpressure.

Consequences: Chronic high operating temperatures shorten compressor lubricant life by 50% for every 10 degrees Celsius rise above 80 degrees Celsius, accelerating additive depletion and varnish formation.

Root Cause 5: Temperature Sensor (RTD / Thermocouple) Calibration Drift

Explanation: Platinum resistance temperature detectors (Pt100 or Pt1000) or thermocouple probes degrade due to vibration, thermal cycling, or moisture ingress, causing them to report artificially high temperature readings to the PLC/controller.

Confirmation: Disconnect the RTD from the controller and measure resistance directly with a DMM. Compare the measured resistance to the standard ITS-90 RTD resistance table (e.g., 100 ohms at 0 degrees Celsius, 138.51 ohms at 100 degrees Celsius). Alternatively, verify sensor tip temperature using a calibrated surface probe pyrometer.

Consequences: Nuisance tripping interrupts production even when actual internal temperatures are normal, leading to operator workarounds or unnecessary hardware replacement.

8. Procédures de résolution étape par étape

Resolution 1: Correcting Low Oil Level & Replenishing Fluid

  1. Execute full LOTO on the compressor electrical supply and bleed all air pressure from the receiver tank to 0.0 bar / 0 psi.
  2. Inspect all joints, hoses, shaft seals, and oil filter spin-on gaskets for signs of leakage. Repair or replace compromised fittings.
  3. Remove the oil fill plug slowly to ensure no residual trapped pressure exists.
  4. Pump or pour OEM-specified synthetic compressor lubricant (ISO VG 46 or 68 depending on ambient spec) into the receiver tank until the fluid level reaches the 3/4 mark on the sight glass with the system settled.
  5. Secure the fill plug with a calibrated torque wrench to the manufacturer’s specified torque (typically 45-60 Nm).
  6. Clear LOTO, restart the compressor in unload mode for 5 minutes, check for leaks, then load the unit and monitor discharge temperature stabilization (Target: 78 – 85 degrees Celsius).

Resolution 2: Cleaning and Flushing the Oil Cooler

  1. Execute LOTO on electrical and pneumatic energy sources.
  2. Allow the cooler core to cool below 40 degrees Celsius (104 degrees Fahrenheit).
  3. External Cleaning: Using compressed air (regulated to < 2.0 bar / 30 psi) or a soft-bristle brush, blow out dust and debris from the cooling fins in the reverse direction of normal airflow. For greasy residue, apply an industrial alkaline biodegradable coil cleaner, allow 10 minutes dwell time, and rinse gently with low-pressure water, ensuring electrical components are fully shrouded.
  4. Internal Flushing (if oil-side fouled): Disconnect oil lines from the cooler inlet and outlet manifolds. Circulate a specialized varnish-removal solvent or flushing oil through the core using an external pump rig for 2 to 4 hours in accordance with ASTM standards. Flush thoroughly with clean compressor oil before reassembly.
  5. Re-torque all hydraulic line fittings to correct standards (e.g., JIC flare or DIN fittings per ISO 8434-1).
  6. Restart and verify Delta-T across the cooler exceeds 12 degrees Celsius under full load.

Resolution 3: Replacing the Thermostatic Mixing Valve Element

  1. Execute LOTO and depressurize the compressor system completely.
  2. Drain oil from the thermostatic valve housing down to a level below the valve cover.
  3. Remove the retaining bolts on the thermostatic valve cover plate and lift off the cover. Extract the O-ring seal and the wax element assembly.
  4. Inspect the internal bore for varnish or scoring. Clean the housing bore with fine emery cloth (600 grit) and solvent cleaner.
  5. Install a new thermostatic element kit (ensuring the correct nominal temperature rating, e.g., 71 degrees Celsius / 160 degrees Fahrenheit nominal start-to-open). Fit a new O-ring seal lubricated with clean compressor oil.
  6. Bolt down the cover evenly in a cross-pattern to 25 Nm torque.
  7. Top off the oil level, clear LOTO, and test compressor warm-up cycle. Verify that oil flows to the cooler once discharge temperature reaches the valve setpoint.

Resolution 4: Remediating Ventilation and Ambient Conditions

  1. Verify compressor room exhaust fan electrical supply, rotation direction, and belt tension. Clean intake louvers and removable pre-filters.
  2. If room ambient temperature exceeds 40 degrees Celsius, install auxiliary ducted fresh air supply fans drawing from outside the building envelope, sized to meet total heat rejection requirements (typically 3.5 m3/min per kW of compressor motor power per CAGI/Pneurop guidelines).
  3. Ensure hot air discharge ducting from the compressor enclosure has zero static pressure restriction and discharges directly outdoors without recirculation.
  4. Verify motor current draw with a clamp meter to ensure cooling fans are not overloaded.

Resolution 5: Replacing and Calibrating Temperature Sensors

  1. Execute LOTO on the electrical supply. Open the control panel.
  2. Disconnect the Pt100/Pt1000 RTD sensor leads from the analog input module.
  3. Unscrew the sensor probe from the discharge manifold thermowell.
  4. Test the removed sensor in a calibrated dry-block calibrator or ice bath (0 degrees Celsius) and boiling water (100 degrees Celsius) using a DMM. If resistance deviates more than +/- 0.5% from the ITS-90 reference table, discard the sensor.
  5. Install a new replacement RTD sensor with thread sealant suitable for high-temperature service (rated to 150 degrees Celsius). Torque to 15 Nm.
  6. Reconnect wiring to the PLC terminal block, verify loop integrity, and perform a live read check via the compressor human-machine interface (HMI).

9. Mesures préventives

Cause fondamentale Stratégie de prévention Méthode de surveillance Intervalle recommandé
Low Oil Level Establish daily pre-start inspection routine; monitor daily oil makeup volume. Daily visual check of receiver sight glass; low-level alarm interlock verification. Quotidiennement / Toutes les 8 heures de fonctionnement
Encrassement du refroidisseur Install intake pre-filters on compressor room louvers; schedule cleanings based on dust load. Monthly thermal imaging of cooler matrix; differential pressure monitoring across air-side core. Monthly cleaning; Quarterly thermal audit
Défaillance de la vanne thermostatique Prevent oil oxidation by adhering to strict oil change intervals (synthetic polyolester / PAO oils). Scheduled oil sample analysis (Spectrochemical wear metals, TAN, viscosity). Every 2,000 hours or Annually (oil analysis every 1,000 hours)
Ventilation Failure Maintain room cooling fans and clean louvers; enforce maximum ambient temp limits (< 40 degrees Celsius). Ambient room temperature datalogger installed near compressor intake. Bi-annual inspection and filter replacement
Sensor Calibration Drift Use industrial-grade RTDs with vibration-resistant potting; periodic calibration check. Compare HMI temperature readout against calibrated infrared pyrometer gun. Annually during scheduled plant shutdown

10. Pièces de rechange et composants

Description de la pièce Specification Quand remplacer Catégorie UNITEC
Thermostatic Valve Element Kit 71 degrees Celsius / 160 degrees Fahrenheit rating, brass/wax core with Viton O-rings Every 8,000 operating hours or upon sticking failure Thermal Management / Compressor Spares
Pt100 RTD Temperature Sensor Class A, 3-wire, 1/4″ NPT thread, -50 to +200 degrees Celsius When calibration drift exceeds +/- 1.5 degrees Celsius Instrumentation & Control
Lubrifiant synthétique pour compresseur ISO VG 46 / PAO-ester blend, food-grade or industrial grade Every 4,000 to 8,000 hours (oil analysis dependent) Fluids & Lubricants
Élément séparateur air/huile Coalescing media with grounding stapling, max 0.2 bar initial dP Every 4,000 operating hours or when dP exceeds 0.8 bar Éléments de filtration
Spin-on Oil Filter Element 10-micron filtration rating, 15 bar burst pressure, internal bypass valve Every 2,000 operating hours with scheduled oil changes Éléments de filtration

To source OEM-equivalent replacement parts, thermostatic kits, sensors, and lubricants engineered for industrial rotary screw compressors, explore the UNITEC-D E-Catalog.

11. References

  • ANSI / CAGI – Performance Standard for Rotary Screw Compressors.
  • ASME Boiler and Pressure Vessel Code (BPVC) – Section VIII, Division 1 (Compressed Air Receivers).
  • OSHA 29 CFR 1910.147 – The Control of Hazardous Energy (Lockout/Tagout).
  • BS EN 1037 / PUWER 1998 – Safety of Machinery – Prevention of Unexpected Start-up (UK).
  • IEEE 43 – Recommended Practice for Testing Insulation Resistance of Rotating Machinery.
  • UNITEC-D Maintenance Engineering Bulletin: Rotary Screw Thermal Management Best Practices (Doc REF: UDM-TR-049).

Related Articles

Dépannage de la température de décharge élevée du compresseur à vis

Technical analysis: Troubleshooting screw compressor high discharge temperature: oil level, cooler fouling, thermostat f

Dépannage de la température de décharge élevée du compresseur à vis
This guide provides a systematic approach for diagnosing high discharge temperature in screw compressors, covering oil level, cooler fouling, thermostat failure, and ambient conditions. Technicians wi

1. Description et portée du problème

La température de refoulement élevée (HDT) dans les compresseurs rotatifs à vis est un indicateur critique de l'inefficacité du système, de la dégradation des composants et d'une défaillance catastrophique potentielle. Ce guide concerne les compresseurs à vis refroidis par air et par eau fonctionnant dans des environnements industriels. HDT est défini comme des températures de fonctionnement dépassant le seuil de décharge recommandé par le fabricant, entraînant généralement un arrêt automatique de la machine pour protéger le bloc air. Le non-respect de cette condition entraîne une oxydation rapide de l’huile, une défaillance des roulements et une usure mécanique prématurée.

Classification de gravité : Critique. Un fonctionnement continu au-dessus de 105 °C (221°F) compromet l'intégrité de l'huile et réduit la durée de vie des composants de 50 % pour chaque augmentation de 10 °C au-dessus des limites de fonctionnement normales.

2. Précautions de sécurité

AVERTISSEMENT : LES SYSTÈMES DE COMPRESSEUR CONTIENNENT DE L'ÉNERGIE STOCKÉE. AVANT D'EFFECTUER TOUTE TÂCHE DE DIAGNOSTIC OU DE MAINTENANCE, EFFECTUEZ LES PROCÉDURES COMPLÈTES DE VERROUILLAGE/ÉTIQUETAGE (LOTO). ISOLEZ LE COMPRESSEUR DE L'ÉNERGIE ÉLECTRIQUE, ÉVACUEZ TOUTE LA PRESSION D'AIR VERS L'ATMOSPHÈRE ET LAISSEZ LE SYSTÈME REFROIDIR EN DESSOUS DE 40 °C (104 °F) POUR ÉVITER LES BRÛLURES THERMIQUES. UTILISEZ UN EPI APPROPRIÉ, Y COMPRIS DES GANTS THERMIQUEMENT ISOLÉS, DES LUNETTES DE SÉCURITÉ ET DES BOTTES À BOUT D'ACIER.

3. Outils de diagnostic requis

Nom de l'outilSpécification/ModèlePlage de mesureObjectif
Caméra infrarougeSensibilité thermique < 0,05°C-20°C à 500°CIdentification des bouchons de refroidisseur et détection des points chauds
Thermocouple numériqueType K, précision de classe 1-50°C à 1200°CVérification des températures de l'air de refoulement et de l'huile
AnémomètreType à palettes ou à fil chaud0 à 20 m/sMesure du débit d'air de refroidissement à travers l'armoire
Manomètre différentielÉchelle de 0 à 2 bars0 à 2 barsTest du filtre à huile et de la chute de pression du refroidisseur

4. Liste de contrôle pour l'évaluation initiale

Vérifier l'articleActionSeuil/Remarque
Niveau d'huileVérifier le niveau d'huile au voyant sous chargeDoit être dans la plage de fonctionnement
Conditions ambiantesEnregistrer la température ambiante de l’air d’admissionCible : < 35°C (95°F)
Heures d'ouvertureVérifier le contrôleur pour la date de la dernière maintenanceComparez avec l'intervalle d'entretien
Historique des alarmesExaminer le journal du contrôleur pour connaître la fréquence du HDTEst-ce soudain ou progressif ?

5. Organigramme de diagnostic systématique

  1. Symptôme : Alarme de température de décharge élevée
    • Étape 1 : Vérifiez la température réelle. Utilisez un thermocouple numérique calibré au niveau du tuyau de décharge. Si la lecture du capteur est significativement différente de la lecture de la jauge, le capteur de température est défectueux.
    • Étape 2 : Vérifiez la température ambiante et la ventilation. Vérifiez la température ambiante. L'air d'admission est-il restreint ? Si la température ambiante est > 40°C, le système surchauffera.
    • Étape 3 : Analysez le refroidisseur d'huile. Utilisez la caméra infrarouge pour rechercher des points froids sur les ailettes du radiateur.
      • S'il existe des points froids, le refroidisseur est encrassé (interne ou externe).
      • Si tout le refroidisseur est chaud, l'huile ne contourne pas ou le thermostat est bloqué.
    • Étape 4 : Vérifiez le fonctionnement du thermostat d'huile. Vérifiez la température de la conduite d'huile menant au refroidisseur. Si la conduite reste froide malgré une température de refoulement élevée, le thermostat est en panne en position de dérivation.

6. Matrice des causes de panne

SymptômeCause probableTest diagnostiqueRésultat attendu
HDT + niveau d'huile basConsommation/fuite d'huileInspection visuelle du voyantNiveau inférieur à l'indicateur minimum
HDT + ΔT élevé sur le refroidisseurEncrassement du refroidisseur externeInspection par caméra infrarougeDégradé de température important sur les ailerons
HDT + faible ΔT sur le refroidisseurThermostat en panne (fermé)Test tactile du tuyau d'arrivée du refroidisseurLe tuyau reste froid sous charge
HDT + Ambiance élevéePanne de ventilationThermomètre d'ambianceTempérature ambiante > 40°C

7. Analyse des causes profondes pour chaque défaut

7.1 Niveau et qualité de l'huile

L'huile sert à la fois de lubrifiant et de liquide de refroidissement dans les compresseurs à vis. De faibles niveaux d’huile réduisent le volume de fluide caloporteur, entraînant une surcharge thermique. De plus, la dégradation de l'huile (boues/vernis) augmente la friction et limite le transfert de chaleur.

7.2 Encrassement du refroidisseur

L'encrassement externe se produit lorsque les filtres d'admission tombent en panne, permettant à la poussière et aux débris de boucher les ailettes du radiateur, réduisant ainsi l'efficacité de l'échange thermique. L'encrassement interne se produit lorsque des produits de dégradation de l'huile se déposent à l'intérieur des tubes du radiateur, créant ainsi une barrière thermique.

7.3 Panne du thermostat

Le thermostat d'huile régule le débit d'huile vers le refroidisseur. En cas de panne en position fermée (dérivation), l'huile chaude est renvoyée directement vers le bloc compresseur sans passer par le refroidisseur. Cela entraîne une augmentation immédiate de la température sous charge.

7.4 Conditions ambiantes

Les compresseurs à vis sont conçus pour fonctionner dans des limites de température ambiante spécifiques. Des températures ambiantes élevées réduisent le ΔT disponible pour le transfert de chaleur, obligeant le compresseur à chauffer plus.

8. Procédures de résolution étape par étape

8.1 Résolution d'un niveau d'huile bas

  1. Effectuez LOTO.
  2. Laissez le système se dépressuriser complètement.
  3. Inspecter l'absence de fuites (raccords, durites, joint d'huile).
  4. Ajoutez du lubrifiant approuvé par le fabricant jusqu'au niveau approprié.
  5. Vérifiez l'état du filtre à huile (s'il est restreint, le débit d'huile est entravé).

8.2 Résolution de l'encrassement du refroidisseur

  1. Effectuez LOTO.
  2. Externe : Utilisez de l'air comprimé (en dessous de 2 bars) ou une solution détergente douce pour nettoyer le pack d'ailettes. N'utilisez pas de nettoyeurs haute pression car ils pourraient effondrer les ailettes.
  3. Interne : en cas de suspicion, rincez le système de refroidissement à l'aide d'un solvant de rinçage à l'huile recommandé conformément au bulletin technique du fabricant.

8.3 Résolution d'une panne du thermostat

  1. Effectuez LOTO.
  2. Localisez le boîtier du thermostat (généralement près du bloc air).
  3. Retirez le couvercle du boîtier et extrayez l'élément thermostatique.
  4. Testez l'élément dans un bain d'eau chaude (il doit s'ouvrir à la température nominale, généralement 70-80°C).
  5. Remplacez par un nouvel élément et un nouveau joint. Serrez selon les spécifications de couple.

9. Mesures préventives

Cause fondamentaleStratégie de préventionMéthode de surveillanceIntervalle recommandé
Niveau d'huileContrôle de niveau quotidienVérification du voyantQuotidiennement
Encrassement du refroidisseurFiltration de l'air d'admissionSurveillance de la pression différentielleMensuel
ThermostatiqueAnalyse d'huile régulièreTest de performance annuelAnnuellement
AmbianteOptimisation de la ventilationSonde de température ambianteContinu

10. Pièces de rechange et composants

Description de la pièceSpécificationQuand remplacerCatégorie UNITEC
Élément de thermostat d'huileSpécifique au fabricant d'équipement d'origineToutes les 8 000 heures de fonctionnementPièces de rechange pour compresseur
Filtre à huilePlein débit, 10 micronsToutes les 2 000 à 4 000 heuresKits d'entretien
Ensemble refroidisseurSpécifique au fabricant d'équipement d'origineSi l'encrassement interne est irrécupérableComposante majeure

Pour toutes les pièces de rechange, consultez le catalogue électronique UNITEC-D : https://www.unitecd.com/e-catalog/

11. Références

  • ASME PTC 9 : Code de test de performance pour les compresseurs
  • ANSI/CAGI B19.1 : Norme de sécurité pour les systèmes à air comprimé
  • Manuels de service technique OEM pour la lubrification et le contrôle thermique