1. Area of execution and purpose
This guide is intended for technical personnel performing maintenance of cooling systems in industrial installations using coolant fluid to ensure effective machining and processing. The purpose of this guide is to ensure proper execution of coolant concentration testing, pH control, removal of tramp oil, and filter replacement in order to ensure high quality processing and equipment longevity.
2. Safety
Important: Before performing any work, turn off the system power, apply mechanical isolation, and install "Do not operate" tags. Use personal protective equipment (gloves, goggles, mask), especially when working with chemical liquids and high pressure.
3. Required Tools and Materials
| Tool Name | Specification | Quantity |
|---|---|---|
| Torque wrench with torque indicator | Range 10–100 Nm | 1 |
| Multimeter | Measurement range 0–500 V, 0–10 A, 0–20 MOhm | 1 |
| pH Meter | Size 150 mm, accuracy ±0.1 pH | 1 |
| Electric measuring tank | Capacity 20 l, temperature 15–90 °C | 1 |
| Coolant Fluid Filter | Minimum flow 15 l/min | 1 |
| Thrombolytic pump | Maximum pressure 10 bar | 1 |
| Manual for measuring the thickness of the layer | Minimum accuracy 0,01 mm | 1 |
4. Inspection Before Maintenance
| Item | Check | Acceptance/Rejection Criterion | Notes |
|---|---|---|---|
| 1 | Power Off | Plates "Do not operate" | It is necessary |
| 2 | Absence of pressures | System pressure less than 0.5 bar | It is necessary |
| 3 | Protection against electric shock | Protective gloves, goggles, mask | It is necessary |
| 4 | Absence of open liquids | The liquid does not spill | It is necessary |
| 5 | Clean filter | Surface clean | It is necessary |
5. Step by Step
- Preparation for Operation
Perform all checks from section 4. Turn off the power and install "Do Not Operate" tags. Open the drain valve for the cooling liquid.
Error: check for absence of pressure before opening the valve.
- Measurement of Coolant Concentration
Take a sample of the liquid and measure 100 ml into the measuring container. Use the reagents for determining the coolant concentration according to the manufacturer.
Помилка: не використовувати реагенти, які не відповідають стандарту ISO 4406.
Correct concentration: 5–10% of the total mass of the liquid.
- pH Control
Prepare the liquid sample for pH measurement. Use a pH meter. The pH value should be in the range of 8.5–9.5.
Помилка: не використовувати вимірювальну піхту, яка не відповідає стандарту ISO 10524.
- Thrombolytic Oil Removal
Connect the thrombolytic oil remover to the system. Set the pressure to 8 bar. Measure the oil layer thickness on the bearings and in the compartments. The thickness should not exceed 0.1 mm.
Error: do not set pressure higher than 10 bar.
- Filter Replacement
Remove the old filter using a torque wrench with a torque screwdriver. Install the new filter with the recommended lubrication torque (20 Nm). Check for any leakage.
Помилка: не використовувати фільтр, який не відповідає стандарту ISO 3720.
- System Connection
Return the power to the system. Turn off the "Do Not Operate" tags. Check for no leakage or pressure deviation.
Error: pressure not checked after switching on.
6. After maintenance inspection
| Test | Expected result | Actual Result | Pass/Fail | |
|---|---|---|---|---|
| 1 | Coolant Concentration | 5–10% | ||
| 2 | pH | 8.5–9.5 | ||
| 3 | Oil layer thickness | ≤ 0.1 mm | ||
| 4 | System pressure | 2–5 bar | ||
| 5 | Flow | Absence |
7. Troubleshooting
| Symptom | Possible cause | Appropriate action |
|---|---|---|
| Reduction of processing efficiency | Incorrect coolant concentration | Measure the concentration and restore to the recommended level |
| Electric arc | Filter contamination | Replace filter |
| Overtemperature | Coolant Fluid Contamination | Remove thrombolytic oil |
| Incorrect pressure | Incorrect amplifier settings | Check the pressure and set to 8 bar |
| Fluid leakage | Incorrect filter installation | Check the filter torque |
8. Recommended Maintenance Plan
| Task | Frequency | Estimated duration | Skill Level |
|---|---|---|---|
| Concentration testing | Monthly | 10 min | Average |
| pH Control | Monthly | 10 min | Average |
| Thrombolytic Oil Removal | Quarterly | 30 min | Experienced |
| Filter Replacement | Quarterly | 20 min | Average |
9. Special Parts
| Description | General specification | Category UNITEC-D |
|---|---|---|
| Coolant Fluid Filter | Minimum flow 15 l/min | 12345 |
| Concentration measurement reagent | For concentration 5–10% | 67890 |
| pH Measurement Probe | Accuracy ±0.1 pH | 54321 |
| Thrombolytic pump | Maximum pressure 10 bar | 98765 |
Contact UNITEC-D for high-quality components: https://www.unitecd.com/e-catalog/
10. References
- ISO 4406: Standard for the determination of the cleanliness of the cooling fluid
- ISO 10524: Standard for pH measurement
- ISO 3720: Standard for Coolant Fluid Filters
- Manufacturer's Documentation for CNC Equipment
- DSTU 4365-2009: Requirements for Technical Operation of Industrial Equipment