Introduction
The safe operation of industrial facilities, especially those working with flammable gases, vapors, dusts or flammable liquids, is critically important. Explosive atmospheres pose a significant risk to personnel, equipment and the environment. ATEX directives (from the French "Atmosphères Explosibles") is a fundamental regulatory act of the European Union aimed at preventing explosions and protecting the health and safety of workers. In Ukraine, these requirements are implemented through national standards of the DSTU EN series. Ensuring compliance of all components, in particular spare parts, with these standards is not only a legal requirement, but also a basic prerequisite for uninterrupted and safe production.
Scope and obligation
The ATEX directives consist of two main parts: Directive 2014/34/EU covers equipment and protective systems intended for use in potentially explosive atmospheres, while Directive 1999/92/EC sets minimum requirements to improve the safety and health of workers exposed to the risk of exposure to explosive atmospheres. These standards are mandatory for all enterprises where the formation of explosive gas, vapor or dust mixtures with air is possible.
ATEX compliance applies to a wide range of industries, including oil and gas, chemical, pharmaceutical, food, woodworking, mining, and energy. The equipment covered by these directives includes electrical and non-electrical devices: electric motors, pumps, valves, sensors, control panels, lighting devices, cables, seals, bearings and many other components that can be a source of ignition or operate in an explosive area. Compliance is the responsibility of business owners, operators, heads of maintenance departments and purchasing departments.
Basic requirements
Compliance with ATEX requirements is based on a comprehensive risk assessment and subsequent classification of potentially explosive areas. This classification defines the type and level of protection required for equipment and components. Below is a summary table of the main liabilities:
| Zone (Gas/Steam) | Zone (Dust) | Description | Equipment category (Gas/Dust) | Equipment Protection Level (EPL) | An example of equipment |
|---|---|---|---|---|---|
| 0 | 20 | Permanent or prolonged presence of an explosive atmosphere | 1G / 1D | Ga / Da | Level sensors, mixer fans, located inside the tanks |
| 1 | 21 | Probable presence of an explosive atmosphere | 2G / 2D | Gb / Db | Pumps, valves, electric motors in the immediate vicinity of the emission source |
| 2 | 22 | The short-term presence of an explosive atmosphere is unlikely | 3G / 3D | Gc / Dc | Compressors, switchboards, lighting |
The key requirements are:
- Risk assessment and zone classification: Detailed analysis of potential ignition sources and their respective classification according to DSTU EN 60079-10-1 (gases) and DSTU EN 60079-10-2 (dusts).
- Equipment selection: Use only those equipment and spare parts that are certified for the respective zone and category.
- Documentation: Availability of declaration of conformity, ATEX certificates, operating and maintenance instructions.
- Marking: Each component must have a clear ATEX marking (eg
CE Ex II 2G Ex db IIC T6 Gb). - Personnel training: Regular training of all personnel working in explosive areas on risks and safety procedures.
- Maintenance and Inspections: Develop and implement routine inspection and maintenance programs to ensure continued equipment compliance.
Impact on maintenance and repair (MRO) operations
Implementing and maintaining ATEX compliance has a significant impact on all aspects of MRO. This requires a review of existing practices and the introduction of new, more stringent procedures.
Maintenance
Maintenance procedures must be adapted to ATEX requirements. This includes:
- Use of certified tools: All tools used in hazardous areas must be intrinsically safe and be marked accordingly.
- Specific procedures for "hot work": Work that generates heat, sparks or open flames (welding, cutting) requires a work permit and strict controls.
- Regular Inspections: Scheduled inspections of equipment for damage, corrosion, condition of seals and cables, and integrity of protective shells.
- Correct installation and repair: Any repair or replacement of components must be performed in accordance with the manufacturer's instructions and using only original or equivalent certified replacement parts.
Procurement
The purchasing department plays a key role in ensuring ATEX compliance:
- Purchase only certified spare parts: Every spare part intended for use in an explosive area must be accompanied by the appropriate ATEX certificate.
- Verification of suppliers: Cooperation only with reliable suppliers who can provide full documentation and guarantee product compliance.
- Checking documentation: Thorough checking of certificates, declarations of conformity and labeling before accepting the goods.
Documentation
Maintaining accurate and up-to-date documentation is critical to demonstrating compliance:
- Retention of ATEX certificates:Retention of all certificates for equipment and spare parts.
- Risk assessments: Keeping records of zone classification and risk assessment results.
- Inspection logs: Keeping all logs of regular checks and maintenance.
- Maintenance logs: Record of all work performed, spare parts used, and equipment configuration changes.
Requirements for components
Each component used in potentially explosive atmospheres must be appropriately labeled and meet specific requirements. For example, Zone 1, where an explosive atmosphere is likely to be present, may require Category 2G equipment. Typical labeling includes:
- CE symbol: Certifies compliance with European standards.
- The symbol Ex: Indicates that the equipment is intended for use in potentially explosive atmospheres.
- Equipment group: Group I (for mines) or Group II (for surface installations). Most industrial enterprises use Group II.
- Equipment category: 1, 2 or 3 corresponding to zones 0/20, 1/21 or 2/22.
- Environment: G for gas/vapour, D for dust.
- Type of protection: For example,
db(explosion-proof shell),ia(intrinsic safety),e(increased safety),t(dust protection) corresponding to DSTU series EN 60079. - Gas/dust subgroup: For example, IIC for hydrogen/acetylene or IIB for ethylene.
- Temperature class: T1 (450°C) to T6 (85°C), indicating the maximum surface temperature. For example, an electric motor marked T4 cannot exceed 135°C.
- Equipment Protection Level (EPL): Ga, Gb, Gc (for gas) or Da, Db, Dc (for dust) indicating the level of protection against ignition.
For example, bearings for pumps operating in Zone 1 must be certified for non-electrical equipment in accordance with DSTU EN ISO 80079-36 and DSTU EN ISO 80079-37, which ensures that there is no risk of sparking or heating above the temperature class. Seals used in valves for aggressive chemical environments in Zone 0 must not only be chemically resistant, but also must not allow leaks that could create an explosive atmosphere and have an appropriate EPL.
A practical compliance checklist for the maintenance manager
- Is there an up-to-date classification of explosive zones at your company? (Last check: 2025)
- Are all installed electrical and non-electrical components clearly ATEX marked?
- Are ATEX certificates and declarations of conformity available and current for all equipment?
- Are only spare parts with the appropriate ATEX certification for the specific zone used?
- Is compliance of certificates checked when purchasing each batch of spare parts?
- Are special maintenance procedures developed and implemented for ATEX areas?
- Are all tools used in hazardous areas intrinsically safe and certified?
- Are personnel working in potentially explosive areas appropriately qualified and regularly trained? (Last certification: 2026)
- Are there regular checks on the integrity of protective sheaths and cables?
- Does the system of work permits for "hot" and other dangerous operations function?
- Are the grounding and equipotential bonding systems working effectively?
- Are all potential ignition sources (static electricity, hot surfaces, sparks) controlled?
- Are repairs performed only by qualified personnel using certified components?
- Is a complete maintenance log kept, including ATEX components replaced?
- Are ventilation systems tested for their effectiveness in dispersing explosive mixtures?
- Are there clear instructions on what to do in the event of equipment malfunctions in the ATEX zone?
- Are all entrances to explosive areas controlled and restricted?
- Are ATEX requirements taken into account when designing new facilities or upgrading existing ones?
- Do non-electrical components (for example, fans, reducers) meet the requirements of DSTU EN ISO 80079-36 and DSTU EN ISO 80079-37?
- Is there an internal audit system to verify ATEX compliance?
Typical inconsistency problems
Auditors often identify a number of typical violations that can lead to serious consequences:
- Incorrect zone classification: Underclassification or outdated classification, resulting in the use of inappropriate equipment.
- Using non-certified spare parts: Purchasing and installing components without proper ATEX certification or with incorrect labeling.
- Improper installation or repair: Failure to follow the manufacturer's instructions during installation or repair, which may violate the protective properties of the equipment.
- Lack or outdated documentation: Incomplete or missing certificates, declarations, inspection protocols.
- Insufficient staff training: Lack of understanding of risks and safety procedures among employees.
- Lack of regular inspections: Neglecting routine inspections resulting in undetected damage or wear and tear.
- Modifications without re-evaluation: Making changes to equipment without re-assessing the risks and confirming ATEX compliance.
Penalties and liability
Failure to comply with ATEX requirements can result in significant legal, financial and reputational consequences. In Ukraine, according to the Code of Ukraine on Administrative Offenses and the Criminal Code of Ukraine, violation of industrial safety rules related to the operation of explosive objects is punishable by:
- Administrative fines: For company officials - from 500 to 1,000 tax-free minimum incomes of citizens (from 8,500 to 17,000 hryvnias) for the first violation. For repeated violations within a year, fines increase.
- Suspension of activity: State supervision bodies can temporarily or completely suspend the activity of workshops, districts or the entire enterprise until the identified violations are eliminated.
- Criminal liability: In case of serious consequences (industrial injury, death, large-scale destruction), the responsible persons (chief engineer, production manager, occupational safety engineer) may be held criminally liable with imprisonment for a term of up to 8 years (Articles 271, 272 of the Criminal Code).
- Cancellation of insurance policies: Most insurance companies will cancel coverage if the incident occurred due to non-compliance with established safety standards.
- Financial losses: Direct expenses for elimination of the consequences of the accident (recovery of equipment, cleaning of the territory), compensation to the victims, losses from the stoppage of production. For example, the cost of restoring one industrial tank after an explosion can reach 500,000 euros, excluding the costs of environmental remediation.
- Reputational damage: Loss of trust of clients, partners and negative impact on the company's image.
Conclusion
Compliance with ATEX directives is an integral part of risk management in industrial explosive environments. It is an integrated approach covering design, procurement, installation, operation and maintenance. The use of certified spare parts is one of the fundamental pillars of this system. Failure to comply with these requirements not only creates security risks, but also carries significant legal and financial consequences.
UNITEC-D GmbH is a reliable supplier of certified components for use in hazardous areas, ensuring that every part supplied meets the highest safety standards. We offer a wide range of ATEX compliant products including bearings, seals, actuators and other equipment required for your production.
For detailed information on certified components and ensuring ATEX compliance, visit the UNITEC-D E-Catalog.
Sources
- Directive 2014/34/EU of the European Parliament and of the Council of February 26, 2014 on the harmonization of the laws of the Member States regarding equipment and protective systems intended for use in potentially explosive atmospheres.
- Directive 1999/92/EC of the European Parliament and the Council of December 16, 1999 on minimum requirements for improving the safety and health of workers exposed to the risk of exposure to explosive environments.
- DSTU EN 60079 (series of standards): Explosive atmospheres.
- DSTU EN ISO 80079-36:2018. Explosive atmospheres. Part 36. Non-electrical equipment for potentially explosive atmospheres. Basic method and requirements (EN ISO 80079-36:2016, IDT).
- DSTU EN ISO 80079-37:2018. Explosive atmospheres. Part 37. Non-electrical equipment for potentially explosive atmospheres. Protection by structural safety "c", ignition source control "b" and liquid immersion "k" (EN ISO 80079-37:2016, IDT).
- Code of Ukraine on Administrative Offenses, Article 93. Violation of requirements of legislation on labor protection and industrial safety.
- Criminal Code of Ukraine, Article 271, 272. Violation of requirements of labor protection legislation.